background image

Manufacturer:

Warren Rupp, Inc.

A Unit of IDEX Corportion

800 North Main Street

P.O. Box 1568

Mansfield, OH 44902 USA

EC / EU Declaration of Conformity

The objective of the declaration described is in conformity with the relevant Union harmonisation

legislation:  Directive 94/9/EC (until April 19, 2016) and Directive 2014/34/EU (from April 20, 2016).

The harmonised standards have been compared to the applicable standards 

used for certification purposes and no changes in the state of the art technical 

knowledge apply to the listed equipment.

AODD Pumps and Surge Suppressors

Technical File No.:  203104000-1410/MER

AODD (Air-Operated Double Diaphragm) Pumps

EC Type Examination Certificate No. Pumps: KEMA 09ATEX0071 X
DEKRA Certification B.V. (0344)

Meander 1051

6825 MJ Arnhem

The Netherlands

Applicable Standard:

EN13463-1: 2001

EN13463-5: 2003

EN60079-25: 2004

Harmonised Standard:

EN13463-1: 2009

EN13463-5: 2011

EN60079-25:2010

David Roseberry, Director of Engineering

DATE/APPROVAL/TITLE:

18 March 2016

Hazardous Locations Applied:

I M1 c 

II 2 G Ex ia c IIC T5

II 2 D Ex c iaD 20 IP67 T100°C

II 2 G Eex m c II T5

II 2 D c IP65 T100°C

II 1 G c T5

II 1 D c T100°C

II 2 G c T5

II 2 D c T100°C

UNIVERSAL ALL SP

Summary of Contents for Sandpiper HDF1

Page 1: ...ax 419 522 7867 SANDPIPERPUMP COM Copyright 2016 Warren Rupp Inc All rights reserved 9 00 229 NOTE UNIT FURNISHED WITH SUB BAS AND RUBBER FEET AS STANDAR STATIONARY BOLT DOWN USE FEET CAN BE REMOVED Q...

Page 2: ...e internal portions of the pump i e dry running For further guidance on ATEX applications please consult the factory When the pump is used for materials that tend to settle out or solidify the pump sh...

Page 3: ...ECTION 3 EXPLODED VIEW 7 Composite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 10 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot V...

Page 4: ...SPT Tapered Thread Discharge Porting Position D Bottom Your Serial fill in from pump nameplate ______________________________________ __ __ _____ __ ___ __ __ __ Pump Pump Pump Options Discharge Diaph...

Page 5: ...21 C 0 F 18 C Santoprene Injection molded thermoplastic elastomer with no fabric layer Long mechanical flex life Excellent abrasion resistance 275 F 135 C 40 F 40 C UHMW PE A thermoplastic that is hig...

Page 6: ...3 4 FNPT 8 56 217 9 00 229 4X 28 7 MOUNTING HOLE NOTE UNIT FURNISHED WITH SUB BASE PLATE AND RUBBER FEET AS STANDARD FOR STATIONARY BOLT DOWN USE RUBBER FEET CAN BE REMOVED HDF1 HDF25 HEAVY DUTY FLAP...

Page 7: ...check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pu...

Page 8: ...performance A pressure regulating valve should be installed to insure air supply pressure does not exceed recommended limits Air Valve Lubrication The air distribution system is designed to operate W...

Page 9: ...nt of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designe...

Page 10: ...nd Refurbishment Kit For cast iron centers with conductive polypropylene air valve body Bumpers Bushings Gaskets O rings Seals Plungers and Retaining Rings 476 341 000 Air End Refurbishment Kit With n...

Page 11: ...25 360 056 379 Gasket 1 26 360 057 360 Gasket 1 27 360 058 360 Gasket 1 28 518 205 156 Manifold 2 518 205 156 E Manifold 2 518 205 010 Manifold 2 518 205 010 E Manifold 2 518 205 110 Manifold 2 518 20...

Page 12: ...prene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 4...

Page 13: ...Body Valve 1 1C 132 037 357 Bumper 2 1D 165 129 157 Cap End 2 1E 170 032 330 1 4 20 X 3 4 Capscrew 8 1F 560 058 360 7 8 ID X 1 16 CS O Ring 8 Air Distribution Valve Servicing See repair parts drawing...

Page 14: ...retainer 1E Step 2 Remove end cap 1C Step 3 Remove spool part of 1A caution do not scratch Step 4 Press sleeve 1A from body 1B Step 5 Inspect O Ring 1D and replace if necessary Step 6 Lightly lubricat...

Page 15: ...t Valve Spool 1 4E 560 023 360 O Ring 4 4F 675 037 050 Retaining Ring 1 Pilot Valve Servicing With Pilot Valve removed from pump Step 1 Remove snap ring 4F Step 2 Remove sleeve 4B inspect O Rings 4C r...

Page 16: ...ay Diaphragm Service Drawing One Piece Bonded Diaphragm Service Drawing 2 29 20 18 3 54 37 15 55 16 14 34 39 19 17 46 13 40 37 54 52 24 24 32 2 29 20 18 3 54 37 15 55 16 14 34 39 19 17 46 13 40 37 44...

Page 17: ...together Torque values are called out on the exploded view Repeat procedure for second side assembly Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate f...

Page 18: ...irective 2006 42 EC on Machinery according to Annex VIII This product has used Harmonized Standard EN809 1998 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance...

Page 19: ...chnical knowledge apply to the listed equipment AODD Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps...

Reviews: