ELECTRIC ACTUATOR SPECIFICATIONS*
Valve Usage:
E024, E025
[Valve sizes 1/2 to 4 Inch]
E026
[Valve sizes 1 to 6 Inch]
E029, E031
[Valve sizes 1-1/4 to 10 Inch]
______________________________________________________________________________________________
Power supply:
24 VAC ± 20% 50/60 Hz, 24 VDC ± 10%
______________________________________________________________________________________________
______________________________________________________________________________________________
Timing:
90 seconds full stroke max
______________________________________________________________________________________________
Control Signal:
2-10 Vdc (default), 4-20 mAdc [with KR500 (resistor kit)]
______________________________________________________________________________________________
Feedback Signal:
2-10 Vdc
______________________________________________________________________________________________
Signal Failure Direction: E024, E029, E031
Fail Closed or Lower Port Closed (default), or
Fail Open or Upper Port Closed
E025, E026
Fail Closed or Lower Port Closed (default), or
Fail Open or Upper Port Closed
______________________________________________________________________________________________
Power Failure Mode:
E024, E029
Fail-In-Place
E031
Fail-Safe to Signal Failure Direction
E025, E026
Fail Closed or Lower Port Closed (default), or
Fail Open or Upper Port Closed
______________________________________________________________________________________________
Capacitor:
E025, E026
Capacitor charge time 5 to 20 seconds
______________________________________________________________________________________________
Manual Override:
Yes, with supplied Allen Key (4mm E024, E025 / 5mm, E026, E029, E031)
______________________________________________________________________________________________
Construction:
Aluminum die cast Yoke, plastic Housing
______________________________________________________________________________________________
Connections:
3 foot long 4 Conductor 18 gauge wire, pigtail (may include fifth pink colored conductor
only used for factory programming. Do Not Use or Connect)
______________________________________________________________________________________________
Enclosure Type:
NEMA 2, IP54, UL 2
______________________________________________________________________________________________
Noise Level:
E024, E025
45 dBA
E026
60 dBA
E029, E031
65 dBA
______________________________________________________________________________________________
Environmental:
Operating: A 32°F to +122°F (0 to +50°C)
Humidity: 5 to 95% RH non-condensing
Storage: -40°F to +176°F [-40°C to +80°C]
______________________________________________________________________________________________
Orientation:
Factory Aligned per drawings
______________________________________________________________________________________________
Mounting:
Vertical above centerline of valve
______________________________________________________________________________________________
Safety Agency Listing: CE, cULus
* See page 5 for VMS-50 BCM Specifications
Power Requirements
E024
E025
E026
E029
Power consumption running
2 W
3 W
5 W
6 W
Power consumption holding
1.5 W
2 W
2 W
1.5 W
Transformer sizing (24 VAC Class 2)
4 VA
7 VA
9.5 VA
11 VA
Power Requirements
E031‡
Power consumption running
(Battery charging)
12.84 W
Power consumption running
(Battery charged)
7.2 W
Power consumption holding
(Battery charging)
8.34 W
Power consumption holding
(Battery charged)
2.7 W
Switching Power Supply
24 Vdc 2.0 A
‡ E031 is composed of E029 and VMS-50 BCM,
does not include VMS-50 PS
Summary of Contents for E025
Page 16: ...16 2600 Emrick Blvd Bethlehem PA 18020 USA 800 922 0085 www warrencontrols com D3400024...
Page 17: ...17 HVAC_BAC_ELECTRIC_IOM_RevE_0421 D3400025...
Page 25: ...25 HVAC_BAC_ELECTRIC_IOM_RevE_0421 E024 and E029 E031 ON OFF CONTROL...
Page 26: ...26 2600 Emrick Blvd Bethlehem PA 18020 USA 800 922 0085 www warrencontrols com NOTES...