Placement of welding machine
In placement, please pay attention to the following items:
(a) Lay in the place as possible where the ground is flat and vibration is little and which is
more than 20m far from wall.
(b) Please put it in the clean and dry place where iron powder, dust, paint are little.
(c)Please put the machine in the place where rain pouring can be avoided and which is
not subject to the erosion of sea water.
Connection
Grounding
(a) The grounding terminal is set on the bottom of side plate of back of machine shell,
please earth with copper wire with above 6mm2 area.
Please entrust full-time staff (electrician) to earth.
Connection of power
One welding machine is equipped with one distribution box including switch, fuse and
other current protectors, whose output end is connected with input end of welding
machine. The capacity of distribution box refers to the following table. Especially for fuse
and other current protectors, for the sake of safety, please use the protector with proper
capacity rather than the protector with the too great capacity
Connection of welding end
One end connects with the cable of welding tongs, another end connects with welded
object by connection cable. To ensure safety, in operation the welded object must be
earthed.