arner Electric’s FBB series of Electrically

Released Brake Modules are designed for
brake only applications when mounted to the
front of a NEMA C-face motor. The fail safe
brake engages when power goes off.

Failure to follow these

instructions may result in product damage,
equipment damage, and serious or fatal injury
to personnel.

Mounting Instructions

Step 1: Mounting the Brake to a Motor

The brake module can be mounted directly to
the motor as follows:

A. Insert a key in the motor shaft keyway. Prick

punch the end of the motor shaft keyway to
prevent the key from sliding out.

B. Align the motor shaft and key with the mating

shaft hole and key slot in the brake module.

C. Slide the module onto the motor shaft so the

module surface is snug against the motor
face.

NOTE: Brake Module should slide

freely onto shaft and fit flush with motor

C-face.

D. Secure the brake module in the motor C-face

with the four (4) long hex head capscrews.
Suggested torque for capscrews is 30-35
lb.ft.

Step 2: Electrical Connections and
Control Requirements

A. The wiring diagram included with each

Warner Electric control shows the proper
electrical connections to be made.

B. Controls used must have adjustable output

voltage.

C. All Permanent Magnet Type Electrically

Released Brake Modules are polarity
sensitive. Therefore, the (+) red wire must be
connected to the (+) terminal and the
(-) black wire to the (-) terminal.

90 Volt Brake recommended controls are:

CBC-160-1
CBC-160-2
CBC-200
CBC-300
CBC-500-90
CBC-550-90

24 Volt Brake recommended controls are:

CBC-500-24
CBC-550-24

If brake is to be applied with

the brake output shaft in a vertical position
Warner Electric's application engineering
should evaluate application.

EM 210-20 FBB
EM 215-20 FBB
EUM 210-20 FBB
EUM 215-20 FBB

If any problems should occur during
adjustments or application questions arise
please contact:
Technical Support at 1-800-825-9050.
Monday through Friday 7:30 a.m. - 4:30 p.m.
central time.

®

DIST. AUTORIZADO

MEX (55) 53 63 23 31
QRO (442) 1 95 72 60

MTY (81) 83 54 10 18
[email protected]

Summary of Contents for EM-FBB Series

Page 1: ...ructions P 1337 1 819 0317 Electrically Released Brake Module For EM FBB and EUM FBB An Altra Industrial Motion Company DIST AUTORIZADO MEX 55 53 63 23 31 QRO 442 1 95 72 60 MTY 81 83 54 10 18 ventas industrialmagza com ...

Page 2: ...ace with the four 4 long hex head capscrews Suggested torque for capscrews is 30 35 lb ft Step 2 Electrical Connections and Control Requirements A The wiring diagram included with each Warner Electric control shows the proper electrical connections to be made B Controls used must have adjustable output voltage C All Permanent Magnet Type Electrically Released Brake Modules are polarity sensitive T...

Page 3: ...ed to perform the procedure No power is applied to motor during this procedure Power normally supplied by motor to brake control should be supplied by alternate method 1 With power off connect the positive lead of the power supply to the positive red lead of the brake and the negative lead of the power supply to the negative black lead of the brake 2 Connect a volt meter to measure the voltage app...

Page 4: ...under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential indirect or incidental damages of any kind incurred by reason of the manufacture sale or use of any defective product Warner Electric LLC neither assumes nor authorizes any other person to give any other warranty or to assume any other obligatio...

Reviews: