Warner Electric • 800-234-3369
P-239-24-WE
3
Specifications
Input:
CBC-500-90:
120 VAC ± 10%, 50/60 Hz, 1 phase, 250 VA max .
CBC-500-24:
24-30 VAC, 50/60 Hz, 1 phase; or 24-30 VDC, 250 VA max .
CBC-550-90:
120/220/240/380/480 VAC ± 10%, 50/60 Hz, 1 phase, 250 VA max .
CBC-550-24:
120/220/240/380/480 VAC ± 10%, 50/60 Hz, 1 phase, 250 VA max .
Output:
CBC-500-90:
0-90 VDC full-wave rectified nominal,
1 .0 amp per channel max ., 2 .0 amps total
CBC-500-24:
0-24 VDC full-wave rectified nominal,
5 .0 amps per channel max ., 5 .0 amps total
CBC-550-90:
0-90 VDC full-wave rectified nominal,
1 .0 amp per channel max ., 1 .2 amps total
CBC-550-24:
0-24 VDC full-wave rectified nominal,
4 .0 amps per channel max ., 4 .0 amps total
Circuit Protection: (fusing)
CBC-500-90:
2 .5 amp, 250 V fast-blo, 3AG
CBC-500-24:
6 .3 amp, 250 V fast-blo, 5 x 20 mm
CBC-550-90:
1 .5 amp, 250 V fast-blo, 3AG
CBC-550-24:
5 amp, 125 V fast-blo, 5 x 20 mm
Switching Inputs: (external to control, supplied by customer)
Three optically isolated, 10-30 VDC:
Channel 1 Input (adjustable voltage applied to channel 1)
Channel 2 Input (adjustable voltage applied to channel 2)
Channel 2 Override Input (full voltage applied to channel 1)
Maximum off-state leakage < 1 mA
Adjustments:
Channel 1 Voltage (via potentiometer)
Channel 2 Voltage (via potentiometer)
Jumper (selects simultaneous or alternate mode)
Frequency Adjustment: 60-400 Hz (via potentiometer)
Ambient Temperature:
-20° to 122°F (-29° to 50°C)
Auxiliary Supply:
12 VDC, 250 mA maximum
Enclosure:
Optional NEMA 13 enclosure available