background image

Warranty

Warner Electric LLC warrants that it will repair or replace (whichever it deems advisable) any 
product manufactured and sold by it which proves to be defective in material or workmanship
within a period of one (1) year from the date of original purchase for consumer, commercial or
industrial use.

This warranty extends only to the original purchaser and is not transferable or assignable without
Warner Electric LLC’s prior consent.

Warranty service can be obtained in the U.S.A. by returning any defective product, transportation
charges prepaid, to the appropriate Warner Electric LLC factory. Additional warranty information
may be obtained by writing the Customer Satisfaction Department, Warner Electric LLC, 449
Gardner Street, South Beloit, Illinois 61080, or by calling 815-389-3771.

A purchase receipt or other proof of original purchase will be required before warranty service is 
rendered. If found defective under the terms of this warranty, repair or replacement will be made,
without charge, together with a refund for transportation costs. If found not to be defective, you
will be notified and, with your consent, the item will be repaired or replaced  and returned to you
at your expense.

This warranty covers normal use and does not cover damage or defect which results from 
alteration, accident, neglect, or improper installation, operation, or maintenance.

Some states do not allow limitation on how long an implied warranty lasts, so the above limitation
may not apply to you.

Warner Electric LLC’s obligation under this warranty is limited to the repair or replacement of the 
defective product and in no event shall Warner Electric LLC be liable for consequential, indirect, 
or incidental damages of any kind incurred by reason of the manufacture, sale or use of any
defective product. Warner Electric LLC neither assumes nor authorizes any other person to give
any other warranty or to assume any other obligation or liability on its behalf.

WITH RESPECT TO CONSUMER USE OF THE PRODUCT, ANY IMPLIED WARRANTIES WHICH
THE CONSUMER MAY HAVE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF
ORIGINAL CONSUMER PURCHASE. WITH RESPECT TO COMMERCIAL AND INDUSTRIAL 
USES OF THE PRODUCT, THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR 
OTHERWISE, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This warranty gives you specific legal
rights and you may also have other rights which vary from state to state.

Changes in Dimensions and Specifications

All dimensions and specifications shown in Warner Electric catalogs are subject to change without
notice. Weights do not include weight of boxing for shipment. Certified prints will be furnished
without charge on request to Warner Electric.

Warner Electric LLC

449 Gardner Street • South Beloit, IL 61080
815-389-3771 • Fax: 815-389-2582
www.warnerelectric.com

An Altra Industrial Motion Company

P-269   819-0407   9/07

Printed in USA

®

DIST. AUTORIZADO

MEX (55) 53 63 23 31
QRO (442) 1 95 72 60

MTY (81) 83 54 10 18
[email protected]

Summary of Contents for CBC-200 Series

Page 1: ...s Single Channel Adjust Clutch Brake Controls Installation Operating Instructions P 269 819 0407 An Altra Industrial Motion Company DIST AUTORIZADO MEX 55 53 63 23 31 QRO 442 1 95 72 60 MTY 81 83 54 10 18 ventas industrialmagza com ...

Page 2: ... either of the outputs To reset power must be removed the shorted condition cleared and the AC input power reapplied to the control The enclosed version may be used with or without the cover Removal of the plastic cover when the control is used in an enclosure will increase the operating temperature range of the control The chassis mount version does not have a cover and must be mounted in an encl...

Page 3: ...nts Current Range Selection via DIP switch SW1 Current Ranges Switch Setting 1 2 3 4 5 Max Output ma 60 175 245 305 533 3 Warner Electric 800 825 9050 P 269 External Switching Mechanical or electromechanical Electromechanical Customer supplied 1 amp 125 V minimum rating Solid state NPN isolated transistor Customer supplied 2 amp 250V minimum rat ing Maximum off state leakage current 1 ma External ...

Page 4: ...CBC 200 3 control is used the following additional procedure must be followed 1 For the CBC 200 2 remove the knob from the control 2 On the CBC 200 1 CBC 200 2 or CBC 200 3 remove the four screws that hold the faceplate bracket and PC board to the chassis plate 3 Bring the external potentiometer wires through the conduit entrance hole and wire the potentiometers to the appropriate terminals blocks...

Page 5: ...he faceplate with the holes on the PC board 5 Using the 4 40 screws supplied mount the PC board and faceplate assembly to the panel Insure that the faceplate aligns cor rectly and does not contact any of the components on the PC board 6 Tighten all four mounting screws securely 7 If the CBC 200 C or CBC 200 C2 was used insert the knob on the internal poten tiometer shaft 8 Attach the switch settin...

Page 6: ...brakes Figure 3 1 Connect either the clutch or brake magnet to Terminals 4 and 5 Tighten Terminal 4 securely 2 Connect the other magnet either brake or clutch to Terminals 7 and 8 Tighten Terminal 7 securely 3 Connect switching for Channel 1 to Terminals 5 and 6 Tighten both terminals securely 4 Connect switching for Channel 2 to Terminals 8 and 9 Tighten both terminals securely 5 Set DIP Switch S...

Page 7: ...nect the Brake to Terminals 4 and 5 Observe the polarity when making connec tions Tighten Terminal 4 securely 2 Connect the Clutch to Terminals 7 and 8 Tighten Terminal 7 securely 3 Connect the switching for Channel 1 to Terminals 5 and 6 Tighten terminals securely 4 Connect the switching for Channel 2 to Terminals 8 and 9 Tighten terminals securely 5 Set DIP Switch SW1 for proper current setting ...

Page 8: ...te the pot cable through one of the conduit entrance holes on the bottom of the unit and wire to the appropriate terminal block on the PC board Refer to the wiring diagrams on this page for the proper connections CBC 200 1 External Current Limit Adjustment 1 Wire the external current limit potentiome ter to Terminal Block TB 3 for Channel 1 as shown in the diagram See Figure 6 2 If the accessory p...

Page 9: ...heck all wiring for both the poten tiometer and the main terminal block to insure proper connections CBC 200 3 External Current Limit and Level Adjust 1 Wire the external current limit adjust potentiometer to Terminal Block TB 3 for Channel 1 as shown in the diagram See Figure 7 2 If the accessory pot kit is used wire per the color codes as shown 3 Make sure all terminals are securely fastened and...

Page 10: ...stened and the wiring cable is secured so that it can t pull out Note The level adjustment controls both the current adjustable output channel 1 as well as the steady state output channel 2 Chassis Mount Models CBC 200 C1 CBC 200 C2 CBC 200 C3 1 The CBC 200 C series chassis mount version controls are shipped with the face plate bracket assembly loose 2 Wire the control per the appropriate Wiring c...

Page 11: ...0 EC 475 PC 500 SF 650 SF 1525HT SF 250 EM 50 SF 825 SF 825BM SF 400 EM 100 PC 1000 PC 825 EM 180 SF 1225 SF 1000 UM 50 PC 1225 SF 1525 UM 100 PC 1525 EC 650 UM 180 EC 1000 EC 825 UM 50C EM 210 EC 1225 UM 180C UM 210 ATC 55 EUM 50 UM 215 EUM 100 UM 210C EUM 180 EUM 210 EUM 215 Warner Electric PB 120 EB 375 ATB 25 EB 825 EMFB 210 Brake Models PB 170 EB 475 PB 500 EMFB 180 UMFB 210 PB 250 EM 50 PB 6...

Page 12: ...ions and rewire if necessary Torque adjust set to zero 0 Set torque adjustment potentiometer to maximum level Current range switch improperly set Check DIP Switch settings per chart and reset if required No power applied to the control Refer to Symptom A above System incorrectly wired Check wiring per the wiring diagram and rewire if necessary Fail Safe brake used in place Check to insure that a f...

Page 13: ...13 Warner Electric 800 825 9050 P 269 Notes DIST AUTORIZADO MEX 55 53 63 23 31 QRO 442 1 95 72 60 MTY 81 83 54 10 18 ventas industrialmagza com ...

Page 14: ... under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential indirect or incidental damages of any kind incurred by reason of the manufacture sale or use of any defective product Warner Electric LLC neither assumes nor authorizes any other person to give any other warranty or to assume any other obligati...