background image

Warmup Thermostat type WA-XSTAT-V

U S E R   M A N U A L   -   E N G L I S H

Contents

1. Introduction

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  1

2. Getting 

started

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  1

3. General 

Display

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  1

4.  LED

.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   2

5. Buttons

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6. Menus 

for 

Setting 

Up 

the 

Thermostat

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6.1.  Operation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6.1.1. Auto

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6.1.2. Manual

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6.1.3. Comfort

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6.2.  Setting 

4-event

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6.2.1. Example 

of 

Scheduling 

4-event 

Set-up

.  .  .  .  .  .  .  .  .  .  .  .  .  2

6.3.  Programming .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2
6.4.  General 

Settings .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6.4.1. Language .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2
6.4.2. Time

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

6.4.3. Day

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.4.4. Temperature

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.4.5. Child 

lock .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.4.6. Heater .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3
6.4.7. Covering .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3
6.4.8. Sub 

Floor .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.4.9. Application

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.5.  Service

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.6.  Contact 

Details

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.7.  Engineer 

Settings .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.7.1. Readout

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.7.2. Temp. 

Settings

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.7.3. Adaptive 

function .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3

6.7.4. Offset .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4
6.7.5. Fil 

Pilote* .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

6.7.6. Reset .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

7. Error 

Messages

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

8. Factory 

settings .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

9. Appendix

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

9.1.

Table 

of 

Compatibility .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

9.2.

Heat 

Definitions

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

Type: WA-XSTAT-V

1

57628B 11/06 (BJ)

UNDERFLOOR HEATING

UNDERFLOOR HEATING

1. Introduction

The XSTAT-V thermostat can switch on your
heating system at pre-determined times on
different days of the week. It is possible to set 4
periods called events each day with different
temperatures. The thermostat comes with a
default schedule that is suitable for most
installations. Unless you change these settings,
the thermostat will operate to this default
program.

Working with lower temperatures during times
that the room is unoccupied will lower your
energy costs without reducing the comfort. The
thermostat has an adaptive function that
automatically changes the start time of a
heating period so that the desired temperature
is reached at the time that you set. After 3 days
the adaptive function has learned when the
heating must be switched on.

2. Getting started

Quick set-up:
The first time you connect the power or after a
reset, the display will show you “Welcome to
Warmup”.

Push ENTER button. Then you can select:

Language

Time

Day

Temperature

Child lock

Heater?

Covering?

Sub floor

Application

Use the navigation buttons for selecting /
changing in the menus. 

Important:
You have, as minimum, to select “Heater” and
“covering” to define the type of heater and
covering, before you can start up the
thermostat.

For further information, see point: 
5. Buttons.
6.4. General settings.  

3. General Display

The display will normally
show the period (day, night,
home, out), the current
temperature, and the time. 

The period is indicated by a symbol. Below you
can see a list of some of the symbols:

Language
English

.  .  .  .  .  .  page 

4

Spanish .  .  .  .  .  .  page 

8

German .  .  .  .  .  .  page

12

Summary of Contents for WA-XSTAT-V

Page 1: ... schedule that is suitable for most installations Unless you change these settings the thermostat will operate to this default program Working with lower temperatures during times that the room is unoccupied will lower your energy costs without reducing the comfort The thermostat has an adaptive function that automatically changes the start time of a heating period so that the desired temperature ...

Page 2: ...can select the desired temperature for Day and Night for when you are Out and at Home and for the Weekend Day and Weekend Night Moreover you can define when you want each time period Day Night Out Home Weekend Day and Weekend Night to begin Please note You need to use the Down button to move to the end of the menu Finally you can specify temperatures and periods Day Night Out Home for each day of ...

Page 3: ...20 minutes If you for example set the regulator to 50 the thermostat will turn on for 10 minutes switch off for 10 minutes and then turn on again for 10 minutes External Control Used in case of a set up with several thermostats being controlled by an external master thermostat Then the thermostat will work as a slave and you cannot apply any settings at all since the master thermostat controls it ...

Page 4: ...ons is not deleted though 7 Error Messages If you get an error the LED is flashing red Internal failure Contact Warmup External failure Contact Warmup 4 Day 1 5 Event Time With floor sensor With air sensor Day 06 00 08 00 25 C 20 C Out 08 00 16 00 20 C 15 C Home 16 00 22 30 27 C 22 C Night 22 30 06 00 20 C 15 C Day 6 7 Event Time With floor sensor With air sensor Day 08 00 23 00 27 C 22 C Night 23...

Page 5: ... las instalaciones A menos que usted cambie estos ajustes el termostato funcionará con este programa predeterminado El funcionamiento con temperaturas menores durante las horas en que la habitación no esté habitada reducirá sus costes de energía sin sacrificar su comodidad El termostato tiene una función adaptativa que cambia automáticamente la hora de activación de un período de calefacción de ma...

Page 6: ...ra para cada día en un período de 7 días Puede seleccionar la temperatura deseada para el Día y la Noche para cuando usted esté Ausente y En casa y también para Fin de semana Día y Fin de semana Noche Además usted puede definir cuándo desea que comience cada período de tiempo Día Noche Ausente En casa Fin de semana Día y Fin de semana Noche Tome nota Es necesario que utilice el botón Abajo para ll...

Page 7: ...a para el sensor limitador de manera que el termostato se apagará si la temperatura en la ubicación del sensor limitador alcanza el valor máximo seleccionado Esta configuración con un sensor limitador adicional se puede utilizar por ejemplo para evitar daños a algunas cubiertas de piso delicadas Control regulador Contr regulador Aquí no se utiliza ningún sensor El termostato se activará en secuenc...

Page 8: ...te Fil Pilote Encendico Apagado 6 7 6 Reajuste Reajuste 2 Reajusta los valores definidos en Ajustes ingeniería a los valores de fábrica Reajuste 3 Igual que Reajuste 2 excepto que se borran los datos históricos Sin embargo no se borra el número de conexiones de relé 7 7 Mensajes de error Si obtiene un error el LED se iluminará intermitentemente en rojo Error interno Comuníquese con Warmup Error ex...

Page 9: ...ist ab Fabrik mit einem für die meisten Anlagen passenden Zeitplan vorprogrammiert Falls Sie diese Einstellungen nicht ändern arbeitet der Thermostat gemäß diesen Vorgaben Niedrigere Temperaturen in Perioden in denen der Raum nicht benutzt wird bedeuten niedrigere Energiekosten ohne Verminderung des Komforts Der Thermostat verfügt über eine Adaptivfunktion die automatisch den Beginn einer Heizperi...

Page 10: ...s Betriebs Menü auf Auto eingestellt lässt sich das 4 Phasen Programm auf automatische Regelung gemäß den individuellen Temperatur vorgaben für jeden einzelnen Tag über einen Zeitraum von 7 Tagen einstellen Die gewünschten Temperaturen für Tag und Nacht wenn Sie abwesend und wenn Sie anwesend sind für den Wochenendetag und die Wochenendenacht lassen sich einstellen Außerdem können Sie den Zeitpunk...

Page 11: ...h zum im Thermostat eingebauten Fühler kommt ein Begrenzungsfühler zum Einsatz Mit dem Begrenzungsfühler wird eine maximale Grenztemperatur festgelegt der Thermostat schaltet ab wenn die Temperatur am Platzierungsort des Begrenzungsfühlers die maximale Tempera tur erreicht Die Anwendung mit zusätz lichem Begrenzungsfühler empfiehlt sich wenn z B eine Beschädigung von empfindlicher Bodenabdeckung v...

Page 12: ...itte beachten Das Fil Pilote Menü ist nur in Typ WA XSTAT VB verfügbar Kommt haupt sächlich in Frankreich zur Anwendung Öko Temp Spartemperatur Frostsicherungstemp Frostsich temp Frostschutz Fil Pilote Ein Aus 6 7 6 Reset Rückstellung 2 Rückstellwerte sind unter Technische Einstellungen als Fabrikein stellungen festgelegt Rückstellung 3 Gleich wie Rückstellung 2 jedoch historische Daten werden gel...

Reviews: