7
Floor Heating -
Quick Install Guide
•
Channel a groove in the
subfloor for the coldtail &
termination joints, enabling
them to fit flush with the top of
the heater. DO NOT tape over
these joints!
•
Install the floor sensor
centrally between two runs of
the heater.
•
Lay tiles or levelling compound
over the system.
•
The heater, including its
joints, must be wholly within
the adhesive or levelling
compound and not exposed.
•
Use flexible grout when
grouting.
•
Connect your Warmup
thermostat.
•
Cut, turn and affix the mat
to the subfloor using self-
adhesive mesh or double
sided tape
•
Any loose heating cable
removed from the mesh must
be installed at no less than
50 mm intervals and tab taped
in place.
•
Test the resistance of the
heating cable after installation
and check against the
previous value to ensure no
damage has occurred.
•
Test the resistance of the
heating cable after tiling and
check against previous values
to ensure no damage has
occurred.
7
9
11
8
10
12