Measure the resistance of the
heating cable and verify it is
still in line with the Resistance
Before reading previously
taken.
•
Stop installation immediately
and contact Warmup if its
resistance has changed
significantly or if it falls
outside the range set out in
the Reference Resistance
Band table.
•
Measure the resistance of
the floor sensor and record
it on the control card. If it’s
resistance is outside the
prescribed range contact
Warmup.
•
DO NOT
tape over the floor
sensor tip it must be in full
contact with the heated
tile adhesive or levelling
compound.
•
Install the floor sensor at least
300 mm into the heated area
it will be controlling. It should
be located centrally between
parallel runs of heating cable
and not in an area influenced
by other heat sources.