7

NOTE:

 If pairing was successful, the LED 

(B)

 will turn green. The device is 

now ready for use. If the LED turns red you will have to try pairing the device 

again.

Once the eTRV has successfully paired to the Smart Hub, 

programming of the device or changes to device settings must be 

done through the konekt app.

If required, you can quickly switch between manual or program 

mode on the eTRV by pressing and holding the Menu/Boost button 

(E)

 for 2 seconds.

You can manually start pairing mode for another 3 minutes by 

pressing the system button 

(B) 

once.

5.2 Mounting

The eTRV is easy to install and can be done 

without draining the heating system as 

long as you have radiators with a suitable 

radiator valve.  

 

The union nut 

(G) 

on the eTRV can be 

directly attached to all valves with a 

standard thread size of M30 x 1.5.

5.2.1 Danfoss RA adapter

The adapter provided is required to attach the eTRV to Danfoss RA valves.

 

The RA adapter is pre-tensioned in order to provide a better fit. If necessary 

use a screwdriver to open the adapter slightly. The Danfoss valve bodies 

have elongated notches around their circumference, which also ensure that 

the adapter is properly seated when it snaps on.

During installation, ensure that the 

pins inside the adapter are lined 

up with the notches on the valve. 

Ensure that a suitable adapter 

for the valve is properly clipped 

on. After clipping onto the valve 

body, attach the adapter using the 

provided screw and nut.

1

2

RA

1

2

5.2.2 Support ring

The valves from different manufacturers may 

have tolerance fluctuations that make the eTRV 

sit more loosely on the valve. In this instance, 

insert the provided support ring into the flange 

before mounting.

Summary of Contents for konekt WIRELESS KW-UKETRV

Page 1: ...konekt W I R E L E S S BY Installation and operating manual konekt Wireless eTRV KW UKETRV ...

Page 2: ...2 Quantity Description 1 Warmup konekt Wireless eTRV 1 Danfoss RA adapter 1 Support ring 1 Nut M4 1 Cylinder head screw M4 x 12 mm 2 1 5 V LR6 mignon AA batteries 1 Quick start guide Package Contents ...

Page 3: ...6 2 Manual operation 9 6 3 Holiday mode 9 6 4 Operating lock 9 6 5 Offset Temperature 9 6 6 Boost Function 9 7 Replacing batteries 9 8 Troubleshooting 10 8 1 Low batteries 10 8 2 Command not confirmed 10 8 3 Duty cycle 10 8 4 Error codes and flashing sequences 10 9 Restore factory settings 11 10 Maintenance and cleaning 11 11 General information about radio operation 12 12 Technical specifications...

Page 4: ... as batteries and packaging preset a risk of choking or suffocation Using the device in any way or for any purpose other than those described in their installation and operation manuals invalidates any warranty or liability This device is intended for use in residential business and commercial properties only Please note that the room temperature control via the radiator thermostat is designed for...

Page 5: ...r Sa Su 12 18 24 Setpoint temperature t U We Th Fr Sa Su 12 18 24 Time and date Fr Sa Su 12 18 24 Operating lock Th Fr Sa Su 12 18 24 Open window symbol e Th Fr Sa Su 12 18 24 Radio transmission Prg Offset Start Ende Low battery t U We Th Fr Sa Su 12 18 24 Holiday mode Prg Offset AUTO MANU BOOST Mo Tu We Th Fr Sa Su 0 6 12 18 24 Start Ende Schedule mode Prg Offset AUTO MANU BOOST Mo Tu We Th Fr Sa...

Page 6: ...nformation 5 Start up 5 1 Pairing device If you have already connected the eTRV to another konekt Wireless device you MUST restore its factory settings first before you can connect it to the Smart Hub see section 9 The Smart Hub must be set up via the konekt App before any other devices can be added to your system For further information refer to the Smart Hub operating manual 5 1 1 Pairing to the...

Page 7: ...irectly attached to all valves with a standard thread size of M30 x 1 5 5 2 1 Danfoss RA adapter The adapter provided is required to attach the eTRV to Danfoss RA valves The RA adapter is pre tensioned in order to provide a better fit If necessary use a screwdriver to open the adapter slightly The Danfoss valve bodies have elongated notches around their circumference which also ensure that the ada...

Page 8: ... appear on the display If the adaption run has been initiated prior to mounting or if an error message F1 F2 F3 is displayed press the menu boost button E and the motor will return to the InS position While AdA is displayed press the menu boost button E to start the adaption run AdA and the activity symbol will displayed During this time no other operation is possible After the adaption run has be...

Page 9: ...y reaches 18 C an offset of 2 0 C may need to be set This will fully open the radiator valves of any eTRVs assigned to the same room to quickly heat the room The boost will last for 5 minutes and can be activated by pressing the menu boost button E or through the app Through the app you can amend the boost duration from 5 30 mins 6 5 Offset Temperature 6 6 Boost Function 7 Replacing batteries If t...

Page 10: ...is exceeded the device may stop working for a brief period The device will start working normally again after a short period max 1 hour 8 2 Command not confirmed 8 3 Duty cycle Device cannot be reached Device is unable to execute the command load failure mechanical block etc Device is defective 8 4 Error codes and flashing sequences Flashing code Meaning Solution F1 Valve drive slow Check whether ...

Page 11: ...ge flashing alternating Update of device software Wait until the update is completed 9 Restore factory settings The factory settings of the device can be restored The device will automatically reconnect to the system and redownload its settings unless it is deleted within the konekt App first Release the system button and then press and hold the system button B again until the orange flashing chan...

Page 12: ...umption 100 mA max Battery life 2 years typ IP Rating IP20 Ambient temperature 0 to 50 C Dimensions W x H x D 56 x 115 x 67 mm Weight 180 g incl batteries Radio frequency band 868 0 868 6 MHz 869 4 869 65 MHz Maximum radiated power 10 dBm Receiver category SRD category 2 Typ open area RF range 250 m Duty cycle 1 per h 10 per h Software class Class A Method of operation Type 1 Degree of pollution 2...

Page 13: ... apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals incorrect installation or damage which occurred while the product was in the possession of a consumer Warmup s sole responsibility shall be to repair or replace the product within the terms stated above WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY IN...

Page 14: ...4 Tudor Estate n Abbey Road n London n NW10 7UW n UK Warmup GmbH n Ottostraße 3 n 27793 Wildeshausen n DE Warmup plc www warmup co uk uk warmup com Tel 0345 345 2288 Fax 0345 345 2299 Warmup OM KW_eTRV V1 2 2021 06 04_EN ...

Reviews: