12
The range of transmission within buildings can differ greatly from
that available in the open air. Besides the transmitting power and
the reception characteristics of the receiver, environmental factors
such as humidity in the vicinity have an important role to play, as do
on-site structural/screening conditions.
11 General information about radio operation
12 Technical specifications
Radio transmission is performed on a non-exclusive RF channel, which
means that there is a possibility of interference occurring. Interference
can also be caused by switching operations, electrical motors or defective
electrical devices.
Warmup konekt Wireless eTRV
Product Code
KW-UKETRV
Supply voltage
2x 1.5 V LR6/mignon/AA
Current consumption
100 mA max.
Battery life
2 years (typ.)
IP Rating
IP20
Ambient temperature
0 to 50 °C
Dimensions (W x H x D)
56 x 115 x 67 mm
Weight
180 g (incl. batteries)
Radio frequency band
868.0-868.6 MHz, 869.4-869.65 MHz
Maximum radiated power
10 dBm
Receiver category
SRD category 2
Typ. open area RF range
250 m
Duty cycle
< 1 % per h/< 10 % per h
Software class
Class A
Method of operation
Type 1
Degree of pollution
2
Valve Connection
M30 x 1.5 mm
Warmup hereby declares that the Warmup konekt Wireless
radio equipment is compliant with RED Directive 2014/53/EU
and Radio Equipment Regulations 2017. Please scan the QR
Code for the Declaration of Conformity.
Do not dispose of the device(s) with regular domestic waste!
Electronic equipment must be disposed of at local collection
points for waste electronic equipment in compliance with the
Waste Electrical and Electronic Equipment Directive.
Declaration of Conformity
Instructions for Disposal