background image

6

Step 3 - Thermostat Mounting

Insert fixing screws through 

mounting holes of the power base 

and tighten.

Re-attach the front housing until a 

“click” is heard. You can now power 

up the thermostat.

1,500W

1

2

System  

type

1,500W

eUFH

2,000W

hUFH

30,000W

Conventional

1,500W

eUFH + relay

Input 

wattage

1

,500W

2

,000W

3

0,000W

1

,500W

Input 

efficiency

90%

90%

Thermostat 

application 

(1-12).

See table 1.0

3

WiFi Setup 

Open  

MyHeating 

app. Scan 

QR Code

3

Follow the on screen icons to set up your system.

Accept

Back/Cancel

Up/Down

Change value/setting

Summary of Contents for Element

Page 1: ...User Guide ElementWiFi Thermostat TM Smart Heating Simplified ...

Page 2: ...l Setup 7 Welcome to the Element thermostat 8 How to quickly change the temperature 8 How to quickly change mode 8 Heating 9 How to set a program 9 Setback Temperature 9 How to set into Manual Mode 10 How to set a Temporary Override 10 Energy Monitor 11 SmartGeo 11 Settings 12 Notifications Error codes 14 Troubleshooting 14 WiFi Troubleshooting 15 Technical Specifications 16 Warranty 17 ...

Page 3: ... installed q q q q For bathroom installations the thermostat MUST be mounted outside of Zones 0 1 and 2 If this is not possible then it must be installed in an adjacent room controlling the rooms using the floor sensor only The thermostat and its packaging are not toys do not allow children to play with them Small components and packaging present a risk of choking or suffocation The thermostat is ...

Page 4: ...nd Neutral Hydronic Underfloor Heating L1 Switched Live to Wiring Centre L2 N3 Supply Live and Neutral N4 Not Used Central Heating L1 Switched Live to Zone Valve Boiler L2 N3 Supply Live and Neutral N4 Not Used For extra low voltage or volt free systems a contactor must be used Connecting the thermostat directly to extra low voltage or volt free boilers may cause damage to the boiler circuit Senso...

Page 5: ... IN OUT of room Floor temperature schedule Floor limit Probe 1 5 6 Floor Sensor Probe 2 6 7 Floor Limit 7 Thermostat OUT of room Air temperature schedule Floor limit Probe 1 5 6 Air Sensor Probe 2 6 7 Floor Limit 8 Thermostat IN OUT of room Regulator schedule No limit Reg None 9 Thermostat IN room Regulator schedule Air limit Reg Internal Air Sensor 10 Thermostat IN OUT of room Regulator schedule ...

Page 6: ...ow power up the thermostat 1 500W 1 2 System type 1 500W eUFH 2 000W hUFH 30 000W Conventional 1 500W eUFH relay Input wattage 1 500W 2 000W 30 000W 1 500W Input efficiency 90 90 Thermostat application 1 12 See table 1 0 3 WiFi Setup Open MyHeating app Scan QR Code 3 Follow the on screen icons to set up your system Accept Back Cancel Up Down Change value setting ...

Page 7: ...ting App and scan the QR Code on the thermostat screen protector or on reverse of the display Follow the instructions in the App to complete setup Download the MyHeating App MyHeating by Warmup 1 2 Step 4 Initial Setup ...

Page 8: ...to set a temporary override If in manual mode this will set a fixed target temperature See How to set into Manual Mode Once the target temperature is set above current floor air temperature the heating indicator will appear in the top right hand corner Mode select allows you to quickly change from manual mode program mode or simply switch the heating off Manual Mode Program Mode Heating OFF Next A...

Page 9: ...pear below the day of the week Press to move to the next day 07 00AM 09 00AM 21 0 04 30PM 09 00PM 21 0 Press to set a program 07 00 09 00 21 0 Set the start time followed by target temperature and finally the end time for that period Press to accept To add remove heating period Press to on the plus minus Up to 5 periods can be set Scroll to the tick and Press to confirm your program Setback temper...

Page 10: ...emperature is selected 23 0 21 0 Sets the target temperature indefinitely Set the duration of the manual mode How to set a Temporary Override Setting a temporary override allows you to set a target temperature which will override your current heating program until your next heating period or for a set duration 17 00 23 0 17 00 20 00 21 0 Sets the override until next scheduled heating period Sets t...

Page 11: ...ystem manufacturer How Energy Monitor works SmartGeo SmartGeo is a unique technology developed by Warmup and built into the MyHeating App that uses an advanced algorithm to understand the most efficient heat settings for your home Working automatically it learns your routines and location through background communication with your smartphone and lowers temperatures when you are away only rising th...

Page 12: ...mostat Application Press to change application Press to confirm 1 10K Change Control Sensor Probe 1 5 6 type Set between 5 10 12 15 100K sensor settings 2 10K Change Limit Sensor Probe 2 6 7 type Set between 5 10 12 15 100K sensor settings 35 0 Set Air limit 35 0 Set Floor limit Set display brightness 4 Set active brightness 2 Day standby brightness 2 Night standby brightness ...

Page 13: ...rgy when the thermostat detects that a window or door has been opened Display lock Switch display lock on 0 0 0 0 Set display lock code Switch display lock off WiFi WiFi Setup Open MyHeating App and scan the QR code on the back of the thermostat display to complete WiFi setup Factory reset Factory reset will erase all of your settings and restore the thermostat to factory defaults ...

Page 14: ...cooling rates for the time of day historic external temperatures and the forecast external temperatures to work out the heating start time in order to reach the comfort time at the start of the comfort period It will only work in Program Mode WiFi Error Symbol WiFi not setup 1 Download and open the MyHeating App 2 Remove thermostat from the wall 3 Scan QR code on the back of the display 4 Place th...

Page 15: ...tach Does the thermostat connect to your WiFi Network Set up a mobile hotspot using a smartphone On a separate device login to the MyHeating app Try to connect the thermostat to this mobile hotspot Does the thermostat connect If the thermostat connected to a mobile hotspot then distance from the thermostat to your router is the likely issue or the signal could be blocked A WiFi repeater extender m...

Page 16: ...mpatibility Electric Hydronic Underfloor Heating Max 16A 3680W Central Heating Systems Combi system boilers with switch live 230V AC input Er P Class IV Warranty 12 Years Approvals BEAB NOTE Hereby Warmup plc declares that the radio equipment type RSW 01 XX YY is in compliance with the RED Directive 2014 53 EU and Radio Equipment Regulations 2017 The declarations of conformity may be consulted by ...

Page 17: ...defect or malfunction was caused by failure to follow the instruction manuals incorrect installation or damage which occurred while the product was in the possession of a consumer Warmup s sole responsibility shall be to repair or replace the product within the terms stated above If the thermostat is installed with a non Warmup heater a three 3 year warranty will apply This warranty does not exten...

Page 18: ...704 Tudor Estate n Abbey Road n London n NW10 7UW n UK Warmup GmbH n Ottostraße 3 n 27793 Wildeshausen n DE Warmup plc www warmup co uk uk warmup com T 0345 345 2288 F 0345 345 2299 Warmup UG Element V1 0 2021 05 07_EN ...

Reviews: