ELECTRICAL CONNECTION
The heater is designed for permanent connection to a
suitable room thermostat. Please refer to the instructions
of the room thermostat.
ATTENTION
:
If the power cord of the unit is damaged, it
must be replaced immediately.
The device is connected with the supplied connector to
a junction box supplying the AC power supply. If a longer
cable is required, it can be replaced by longer one, Type
H05VV-F 3x1.0mm ². A direct connection to a line is
only permitted up to a diameter of 1.5 mm ² (e.g. NYM-J
3x1.5mm ²).
HEATING
The heater is controlled by the externally mounted
thermostat.
GROUNDING
The heater is for use with 120 volts. The green-yellow
grounding of the cord must be connected to a permanent
ground inside the junction box.
Installation and Usage Instruction | LAVA® Design Glass Radiator
5
BLACK
WHITE
GREEN GROUND
2” x 4” ELECTRICAL
BOX FOR TIMER
2” x 4” ELECTRICAL BOX
LAVA Radiant Panel
HOT
LOAD
(black or blue)
GFCI
Protected
Circuit
Hot
Black
Hot
Black
Neutral
White
Neutral
White
Ground
GROUND
(green or yellow)
NEUTRAL LOAD
(white or brown)
THERMOSTAT
ELECTRIC PANEL
Load
Line
Fig 9: Connection diagram