INSTALLATION AND USAGE INSTRUCTION FOR 

THE ELECTRICIAN

 

IMPORTANT

 

NOTES

:

•  Installation and service work must be carried out by a 

licensed professional or a qualifi ed person. Verify that the 
electrical installation complies with the applicable local 
codes. The responsibility of the manufacturer is limited to 
the supply of the device.

•  The devices are designed for wall mounting (vertical 

or horizontal)  with the appropriate accessories (see 
included part list).

•  Wall mounting of the glass radiators corresponds IP24 

Protection.

•  When installing the unit in a bathroom, note the areas of 

protection to local electric code regulations.

•  Specifi ed minimum distances must be respected.

INSTALLATION AND MINIMUM DISTANCES:

LAVA® glass heaters can be mounted horizontally 
or vertically on the wall. They are positioned so that 
fl ammable items can not be ignited. Ensure the required 
minimum distances, particularly to fl ammable objects like 
curtains, and upholstered furniture are correct. Please 
make sure, that the glass radiator can radiate freely into 
open space. (See Fig. 2) 

ATTENTION

: Don’t lean items against the glass or lean the 

radiator against other objects.

ASSEMBLY OF THE RADIATOR:

Please verify that no shipping or handling damage occured 
before installing the power cable to the radiator.

WALL MOUNTING:

1.  Locate the area where the warming panel is going to be 

installed. If electric needs to be installed to panel, fi nd a 
location for the electrical supply and install the proper 
outlet in the wall, placing it near the unit supply cord with 
the plug on rear of the warming panel. We recommend 
using a recessed duplex box (Leviton #689)

(Always turn power off at panel)

2.  Locate area for thermostat. Locate area away from the 

front of the warming panel for the thermostat control 
so it does not affect the unit from operating properly. 
Follow the wiring diagram located with the thermostat 
instruction manual.

3.  Install 2 of the brackets into a stud and then install the 

correct type of wall anchors and mounting hardware 
for the other 2 mounting points -  Please see the hole-
patterns on page 4.  (Anchors for drywall applications are 
included in the box. Anchors for other applications are 
not included and should be sourced locally.)

The installation of the warming panel unit on the wall, 
must be secure.

a. The layout of the bracket locations on the wall should 
be level and plumb. Secure them by using a 2 1/2” (min) 
large screw heads.

b. Install the hanging bolts (supplied) to the back of 
the warming panel unit and leave them extended 
approximately 1/4” to 3/8”.

c. Move the warming panel unit to the place of the 
installation and plug into outlet and hang unit on the 
installed brackets.

4.  Position cable clamp and place LAVA® glass radiators on 

the wall and tighten the screws completely.

5.  To protect the glass radiator against unintentional 

removal, etc. the protection-plate (included in kit) should 
be affi xed to one of the 4 mounting brackets. 
(See pg. 2)

Installation and Usage Instruction | LAVA® Design Glass Radiator

Fig. 2: Minimum mounting distances

3

11.8” / 300mm  

7.8” / 200mm  

11.8” / 300mm  

11.8” / 300mm  

Summary of Contents for LAVA

Page 1: ...LAVA Design Glass Radiator By WarmlyYours Installation Manual Read all instructions before installing or using this heater CAUTION Hot Surface Can cause burns...

Page 2: ...heater must not be placed or mounted directly below a wall socket The heater must not be placed or mounted directly below a wall socket WARNING Covering the glass surface causes overheating danger Ma...

Page 3: ...ctrical and electronic equipment frequently contain valuable materials They may also contain harmful substances that were necessary for their function and safety The residual waste or incorrect treatm...

Page 4: ...ical supply and install the proper outlet in the wall placing it near the unit supply cord with the plug on rear of the warming panel We recommend using a recessed duplex box Leviton 689 Always turn p...

Page 5: ...LAVA 500 LAVA 750 LAVA 1000 Graphic LAVA Glass radiators 250W 500W 750W 100W Hole drilling pattern ATTENTION Verify minimum distances Use required mounting holes and anchors Installation and Usage Ins...

Page 6: ...s only permitted up to a diameter of 1 5 mm e g NYM J 3x1 5mm HEATING The heater is controlled by the externally mounted thermostat GROUNDING The heater is for use with 120 volts The green yellow grou...

Page 7: ...you should avoid excessive use In case of damage ESG shatters into many small pieces with blunt edges to minimize the risk of injury Please note when choosing an installation location that a very sma...

Page 8: ...ion heater and person too great Is the glass radiation heater undersized for the space Are there objects between the person and the glass radiation heater EQUIPMENT MARKINGS Data is included on the ra...

Page 9: ...nufacturing process and tested before shipment to exacting quality control standards If you follow these installation and operating instructions your LAVA glass radiator will provide many years of tro...

Reviews: