Product Construction

The  product  has  a  total  thickness  of  less  than  ¼”  thick  and  is 

constructed in 5 layers:

•  High Density Thermal Anti-slip matting    —insulates and prevents 

the rug from slipping on smooth or polished fl oors. 

•  Reinforced  Aluminum  Foil   —facilitates  heat  dissipation  and 

electrical grounding.

•  Coaxial  Tefzel®  extruded  insulation  warming  element—spaced 

for uniform heating.

•  Reinforced  Aluminum  Foil   —facilitates  heat  dissipation  and 

electrical grounding.

•  Low Density Anti-slip matting—prevents rug from slipping on top 

of the Warmer while allowing heat to transfer through.

Product Diagram

Under Area Rug Heater

24/7 Installation Support  •  Lifetime Technical Assistance  •  (800) 875-5285

www.WarmlyYours.com

Low Density Anti-slip Layer

Reinforced Aluminum Foil Layer 
(heat dissipation & grounding)

Heating Wire

Reinforced Aluminum Foil Layer 
(heat dissipation & grounding)

High Density Insulation Layer

4

Summary of Contents for CP-3646-120

Page 1: ...User Manual for warmlyYours Under Area Rug warmer...

Page 2: ...t or trim the Warmer to fit an area rug that is smaller Never use the Warmer in bathrooms or other wet areas Never shampoo or steam clean an area rug while the Warmer is underneath Never use the Warme...

Page 3: ...faces up Diagram B 4 Remove any excess cord from underneath the Warmer before connecting the power cord to the electrical outlet Plug the Warmer into a standard 120V 15A electrical outlet 5 Select eit...

Page 4: ...of 6 x 6 or larger on top of the warmer Do not overlap multiple warmers Do not shampoo or steam clean rugs while warmer is in place under the area rug WarmlyYours 2 Corporate Dr Long Grove IL 60047 P...

Page 5: ...mer is to gently warm the surface of an area rug to a temperature of up to 100 F bringing soothing radiant warmth to that area of the room The Warmer is portable connects to a standard electrical outl...

Page 6: ...ent spaced for uniform heating Reinforced Aluminum Foil facilitates heat dissipation and electrical grounding Low Density Anti slip matting prevents rug from slipping on top of the Warmer while allowi...

Page 7: ...o UL file E88265 with Low High rocker switch Safety Ratings The system is rated to standard IPX 7 in compliance with the flammability test glow wire test IEC UL94 HB The main electrical plug incorpora...

Page 8: ...oduct without receiving authorization Under this Limited Warranty WarmlyYours com Inc will provide the following remedy If the Product is determined to be defective in materials and workmanship and ha...

Reviews: