5 September 2019
All dimensions are in mm
Copyright
7
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
1.4 PLAN, FRONT ELEVATION & CROSS SECTION
Note:
50mm clearance from the flue liner to timber
framing is required
1
4
1.3 TIMBER FRAMING & TRIM OUT DETAILS
-
HEAT CELL CLEARANCE
Description
TFG 800
TFG 1000
TFG 1200
To centre of flue
J
539
538
589
Flue diameter
K
300
300
350
Liner diameter
L
400
400
450
Heat cell clearance width
M
1290
1490
1690
Heat cell clearance depth
N
890
890
990
Heat cell clearance height
O
2150
2150
2150
Hearth width
P
1350
1550
1800
Hearth projection
Q
500
600
750
Chimney chase clearance
X
500
500
550
Note:
Centreline of flue is NOT in centre of
alcove
Note:
Non
-
combustible cladding eg. 10mm
promina board, 10mm Supalux, latex
plaster etc. (not supplied).