Note: 

When the Base screw is removed, gas will leak from the out let, ensure that the pilot is not adjusted 

or the screw is removed when the fire is burning. 

 

Adjustment of Pilot - 3 Flame : Unscrew Base Screw  as shown in Diagram 2  . 

 

Insert  a  Screw  Driver  as  shown  in  Diagram  3  and  adjust  the  Adjustment  Screw  up  inside  the  3 
Flame Pilot to adjust the Flame Height . 

 

The Flame must always be passing over the Electrodes &/or File Tube on either side . 

 

Replace the Base screw and check for leaks.   

ADJUSTMENT OF HI

LOW PRESSURE                   (SG ONLY )                    (Only to be Adjusted by Gasfitter)

 

ADJUSTMENT OF THE PILOT

3 FLAME                (BOTH SG / EG)                  (Only to be Adjusted by Gasfitter)

 

Note*  Control Valves are Factory Set but may require adjustment onsite . 

Turn Appliance Off & Remove Front Plastic Cover on Igniter , Pull Cover to Slide off . 

Unscrew Test Nipple on the Burner Manifold & fit the Test Gauge Securely - See Diagram 

* To Set the High : Light the Burner & turn to High - Then Adjust the High Screw to the Desired Pressure . See Spec’s 

* To Set the Low : Light the Burner & turn to Low - Then Adjust the Low Screw to the Desired Pressure . See Spec’s 

Extinguish Appliance, remove Test Equipment and Secure Test Nipple . 

* Check Valve & Burner for Correct Operation & check Fire for Gas Leaks . 

Adjustment of High & Low Settings Must be Carried out by a Certified Gas Fitter Only 

3 Flame Pilot in 

Assembled State 

Correct Operation of 

3 Flame Pilot 

Note: to Gas Fitters

 

The 3 flame pilot may need adjustment 
after a period of running time on set up  
as  the  increase  in  heat  in  the  fire  will 

induce  a  higher  draft  in  the  fire,  and 
may  pull  in  flame  away  from  the  File 
Tube causing the fire to shut down.

 

Gas Test 
Nipple for 
SG / EG 
Fires 

Summary of Contents for SG 700

Page 1: ...and tested to comply with NZS 4558 int 2013 Decorative gas log and other fuel effect appliances Keep these instructions for further reference Ensure that you have the correct and current installation...

Page 2: ...TIFIED GASFITTER OR CERTFIED NZHHA SFAIT INSTALLER WHAT S SUPPLIED WHEN ORDERED LEAVE MANUAL WITH THE CUSTOMER ONCE INSTALLED INSTALLER OWNER PLEASE KEEP THESE SPECIFICATIONS FOR FUTURE REFERENCE Supp...

Page 3: ...x 100mm Vents should be fitted 1 at the Top of the alcove and 1 at the base of the Alcove to allow air flow Note Clean and touch up paint on the fire and cover if necessary Stage 3 Finishing Procedur...

Page 4: ...th H 395 395 395 395 395 395 Fascia Width L 1060 1260 1410 1560 940 860 Fascia Height M 680 680 680 680 680 680 Fascia Section N 80 80 80 80 80 80 Hearth Width O 1100 1180 1300 1500 1550 1800 Hearth P...

Page 5: ...ase and at the Top Hebel Cell Firebox Fiberglass Reinforced Mesh 2mm Non Combustible Latex Based Plaster Water Proof Non Combustible Important Note NO Combustible Material to be used below the measure...

Page 6: ...kPa 2 75 kPa 2 75 kPa 2 75 kPa 2 75 kPa Nominal Injector Size mm 2 X 1 3mm 2 X 1 4mm 4 X 1 1mm 4 x 1 2mm 2 X 1 2mm 2 X 1 1mm Burner Pressure High Kpa 2 5 2 5 2 5 2 5 2 5 2 5 Burner Pressure Low Kpa 0...

Page 7: ...LINTH CONSTRUCTION DETAILS Note If Solid Plastering the Heat Cell Structure it is recommended to use a Fibreglass Mesh with a Latex Based Plaster to minimise the chance of the Solid Plaster cracking S...

Page 8: ...600 600 Heat Cell Clearance width J 1210 1210 1210 1610 1610 1610 Heat Sensitive Zone R 1700 1700 1700 1700 1700 1700 IMPORTANT NOTE ALL WARMINGTON FLUELESS GAS FIRES ARE TO BE REBATED INTO ITS ENCLOS...

Page 9: ...o change product specifications without prior notification All Dimension are in mm Copyright 9 GAS SUPPLY ELECTRONICS LOCATION Firebox SG EG 700 SG EG 780 SG EG 900 SG EG 1100 SG EG 1250 SG EG 1500 Fr...

Page 10: ...r of the Installation Cavity through the hole provided A Flare Nut is provided on the Burner for Gas Connection to the Appliance TO THE INSTALLER GAS FITTER ELECTRICIAN FITMENT OF BURNER Burner may be...

Page 11: ...ttered to achieve best Visual Effect Fit Burner Grate by sliding R L Side Metal Pins on Grate into Holes Located on Burner Side Plates as shown below 2 Top Row Slide R LH Grate Pins into Holes located...

Page 12: ...o light all the way across Once the flame is established adjust to the desired setting and close the cover To shut down Open the cover by pulling it outwards Turn the control ignition switch to PILOT...

Page 13: ...e Control Valves are Factory Set but may require adjustment onsite Turn Appliance Off Remove Front Plastic Cover on Igniter Pull Cover to Slide off Unscrew Test Nipple on the Burner Manifold fit the T...

Page 14: ...bserve the following precautions associated with any heating appliance or open fire Do not cover or restrict the fireplace upper or lower vents in any way as this may result in a build up of hazardous...

Page 15: ...s Switched Off due to Power Failure In the circumstance of a Power Failure the Remote Control System will return to the default settings which is a Low Flame and the Fan Turned Off If the Gas Fails to...

Page 16: ...the Power LED will start flashing and after 30 minutes the appliance will Shut Off Automatically By pressing the Timer Button again within the 30 minute period this will reset the Timer and the power...

Page 17: ...TE If setting the Pressure is required it is to be carried out by a certified Gas Fitter If adjustments are necessary remove the cap The Pressure Adjustment Screw and Nut are on the Front Side of the...

Page 18: ...fied that the Appliance is working correctly fit the Front Panel Assembly back to the Gas Burner NOTE Ensure you peel the Protective Plastic Coating from any Stainless Steel components if fitted All B...

Page 19: ...nd LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 19 REMOTE IGNITION EG GAS FIRE WIRING DIAGRAM Modulator Harness Connections Note...

Page 20: ...t be serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTI...

Reviews: