4) Fire Pit Installation  

***We suggest that our products be installed by professionals that are 
locally licensed by the authority having jurisdiction in gas piping. 

Warning: 

We suggest that our products be installed by professionals 

that are locally licensed by the authority having jurisdiction in gas piping. 

Warning: 

We suggest that our products be serviced annually by a 

professional certified in the US by the National Fireplace Institute (NFI) 
as NFI Gas Specialists. 

Warning: 

Confirm this appliance is built for gas used – natural gas 

or LP. Do not use natural gas appliance with LP or LP appliance with 
natural gas. Refer to the label on the appliance. 

Warning: 

To prevent damage, unhook fire pit from gas supply for 

pressure leak tests. 

Warning: 

Fuel line sizing is the responsibility of the installer and 

must be able to supply the stated maximum 60K BTU for the product. 
Natural gas 3.5” WC pressure and for propane 10” WC pressure. 

Warning: 

Burn Testing- It is the responsibility of the qualified 

installer to test for gas leaks at all connections. 

Warning: 

When filling the pan with lava rock and/or decorative 

glass, the instructions in Section 5 must be followed. 

Warning: 

Gas Plumbing Connections: Use only joint compound or 

tape that is resistant to all gases. Apply joint compound to all male pipe 
fittings only- DO NOT use on FLARED fittings. Be sure to tighten every 
joint securely. 

Warning: 

For systems with an extended or detached valve box the 

area in which the valve box is installed must conform with all installation 
requirements to include but not limited to location, construction, venting 
and local codes. Failure to do so may result inpersonal injury property 
damage or explosion. 
  
 

WARRANTY REQUIREMENT:

 Warranty is void if valve box is opened 

 

Purge gas lines of air. 

 

Perform all leak test with leak detector or leak reactant. 

 

Verify correct gas type and pressure. 

 

Perform leak test on main gas supply. Repair leaks as necessary. 

 

Shut Off Gas Supply and Power to fire-pit. 

 

Connect fire-pit to main gas supply. If using flex line avoid sharp 
bends with flex line to prevent whistling. 

 

Turn on gas supply and perform leak test on all inlet connections. 
Repair as needed. 

 

For electronic ignition models hook up proper 110VAC or 24VAC 
electrical power following all local codes. 

 

On electronic ignition models The 6’ power cord can be either tied 
into the main power supply for use with wall switch or plugged 
into remote receiver to use remotely. 

 

Position fire pit safely with access to all gas connections for 

Summary of Contents for HMLS60-NG

Page 1: ...1 DESIGN CERTIFIED CROSSFIRE SYSTEMS HMLS60 24V LP NG DMLS60 3V LP NG MLS60 LP NG...

Page 2: ...e vicinity of this or any other appliance Danger If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from appliance and immediately call gas supplier...

Page 3: ...fire pit is not in use via wall switch or breaker Warning We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We sug...

Page 4: ...Both children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns and clothing ignition Warning Young children should be carefully supervised...

Page 5: ...sed on material size and extended use The vent may work as a drain as well when installed at bottom sidewall to prevent water build up Warning The interior void space of the enclosure surrounding the...

Page 6: ...followed Warning Gas Plumbing Connections Use only joint compound or tape that is resistant to all gases Apply joint compound to all male pipe fittings only DO NOT use on FLARED fittings Be sure to t...

Page 7: ...VER 1 2 MAY CREATE BACK PRESSURE AND GAS LEAKAGE FROM AIR MIXER RESULTING IN LP POOLING UNDER FIRE PIT Warning FOR GLASS MEDIA USAGE WITH LP GAS THE UNIT MUST BE TESTED WITH MEDIA OVER BURNER FOR CONF...

Page 8: ...1 below crossfire burner jets For Electronic Ignition 3 PILOT ASSEMBLY SCREEN Do not cover pilot assemble screen or opening with lava rock or glass Incorrect media installation will cause the pilot f...

Page 9: ...th lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition DO NOT COVER PILOT SCREEN DO NOT COVER PILOT OPENING 6 Parts L...

Page 10: ...ctagon Fire Pit 36SFP 36 Square Fire Pit 42SFP 42 Square Fire Pit 36FP 36 Round Fire Pit 42RFP 42 Round Fire Pit 4830RFP 48 x 30 Rectangle Fire Pit 42RBF Red Brick Schoolhouse 42 Fire Pit HOLLY60 Holl...

Page 11: ...36 Simplicity Fire Bowl CSIMP40 40 Simplicity Fire Bowl HALO36 36 Halo Fire Bowl HALO48 48 Halo Fire Bowl ELEVATED HALO36 36 Elevated Halo Fire Bowl ELAVATED HALO48 48 Elevated Halo Fire Bowl SPIRE Fi...

Page 12: ...ttings and connections 6 For LP models check back pressure with media installed This may need to be done with the pit outside of the enclosure 8 Fire Pit Operation Warning If you do not follow these i...

Page 13: ...vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in section 2 Selecting the Location Warning If lava rock is wet allow fire pi...

Page 14: ...several tries turn the key valve to the OFF position and call your service technician or gas supplier 5 Never leave fire pit unattended by an adult TO TURN OFF GAS APPLIANCE 1 Turn key valve counterc...

Page 15: ...ving the logs and media to allow access to burner Use a paperclip and carefully insert in jet to remove dust spider webs and loose particles from base logs and crossfire burner itself If evidence of d...

Page 16: ...anufacturing defects that prevent safe and correct function as follows Electronics Gas Valve Pilot Assembly Commercial 6mos Residential 1 yr Aluminum plate Brass Crossfire Burner LIFETIME This commenc...

Page 17: ...17 HMLS60 with LP or NG with Honeywell Electronic Spark Ignition System...

Page 18: ...18 DMSL60 with LP or NG with Dexan 3 Volt Battery or 110 Ignition System...

Page 19: ...19 MLS60 with LP or NG Regulator...

Page 20: ...20 System Tags and Markings...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Reviews: