background image

   

16   

 

No Main Burner (Pilot Lights) 

1. Gas Pressure Improper Confirm proper gas pressure (Section 1) 
2. Small Pilot Flame Remove pilot head and clean orifice. ( Section 8) 
3. Dirty Thermocouple Clean using soft brush (Section 8) 
4. Crossfire Burner Obstructed Confirm no debris or water in burner (Always 
cover fire pit!) 
5. Improperly applied Media See (Section 5) 
 

Main Burner Turning Off/On Frequently 

1. Small Pilot Flame Remove pilot head and clean orifice (Section 8) 
2. Improperly applied Media See (Section 5) 
3. Gas Pressure Improper Gas pressure too low (Section 1) 
4. Thermocouple Defective Change Thermocouple. 

 Noise 

1. Whistling Sound Change Flex line routing 
 

 
11) Warranty 

Limited Warranty 
Warming Trends warranties fire pits against manufacturing defects that 
prevent safe and correct function as follows: 

 

Electronics, Gas Valve, & Pilot Assembly: Commercial-6mos; 
Residential- 1 yr. 

 

Aluminum plate, Brass Crossfire Burner: 

LIFETIME

 

 
This commences from the date of original sale / shipment from Warming 
Trends FOB Littleton, Colorado. This warranty is for parts and in-house 
(Warming Trends) labor. The defective product must be sent back to 
Warming Trends with a Return Merchandise Authorization (RMA) issued by 
Warming Trends for that specific product and any other additional 
information for the nature of the defect or warranty claim. 
 
The warranty does not cover items that have been damaged by overheating, 
modification, abuse, flooding or improper storage. Also any labor involving 
installation or maintenance with the unit is not covered. 
 
This warranty excludes claims for consequential, indirect-collateral expenses 
arising from product defects or warranty recovery. 
 

 

Summary of Contents for HMLS60-NG

Page 1: ...1 DESIGN CERTIFIED CROSSFIRE SYSTEMS HMLS60 24V LP NG DMLS60 3V LP NG MLS60 LP NG...

Page 2: ...e vicinity of this or any other appliance Danger If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from appliance and immediately call gas supplier...

Page 3: ...fire pit is not in use via wall switch or breaker Warning We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We sug...

Page 4: ...Both children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns and clothing ignition Warning Young children should be carefully supervised...

Page 5: ...sed on material size and extended use The vent may work as a drain as well when installed at bottom sidewall to prevent water build up Warning The interior void space of the enclosure surrounding the...

Page 6: ...followed Warning Gas Plumbing Connections Use only joint compound or tape that is resistant to all gases Apply joint compound to all male pipe fittings only DO NOT use on FLARED fittings Be sure to t...

Page 7: ...VER 1 2 MAY CREATE BACK PRESSURE AND GAS LEAKAGE FROM AIR MIXER RESULTING IN LP POOLING UNDER FIRE PIT Warning FOR GLASS MEDIA USAGE WITH LP GAS THE UNIT MUST BE TESTED WITH MEDIA OVER BURNER FOR CONF...

Page 8: ...1 below crossfire burner jets For Electronic Ignition 3 PILOT ASSEMBLY SCREEN Do not cover pilot assemble screen or opening with lava rock or glass Incorrect media installation will cause the pilot f...

Page 9: ...th lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition DO NOT COVER PILOT SCREEN DO NOT COVER PILOT OPENING 6 Parts L...

Page 10: ...ctagon Fire Pit 36SFP 36 Square Fire Pit 42SFP 42 Square Fire Pit 36FP 36 Round Fire Pit 42RFP 42 Round Fire Pit 4830RFP 48 x 30 Rectangle Fire Pit 42RBF Red Brick Schoolhouse 42 Fire Pit HOLLY60 Holl...

Page 11: ...36 Simplicity Fire Bowl CSIMP40 40 Simplicity Fire Bowl HALO36 36 Halo Fire Bowl HALO48 48 Halo Fire Bowl ELEVATED HALO36 36 Elevated Halo Fire Bowl ELAVATED HALO48 48 Elevated Halo Fire Bowl SPIRE Fi...

Page 12: ...ttings and connections 6 For LP models check back pressure with media installed This may need to be done with the pit outside of the enclosure 8 Fire Pit Operation Warning If you do not follow these i...

Page 13: ...vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in section 2 Selecting the Location Warning If lava rock is wet allow fire pi...

Page 14: ...several tries turn the key valve to the OFF position and call your service technician or gas supplier 5 Never leave fire pit unattended by an adult TO TURN OFF GAS APPLIANCE 1 Turn key valve counterc...

Page 15: ...ving the logs and media to allow access to burner Use a paperclip and carefully insert in jet to remove dust spider webs and loose particles from base logs and crossfire burner itself If evidence of d...

Page 16: ...anufacturing defects that prevent safe and correct function as follows Electronics Gas Valve Pilot Assembly Commercial 6mos Residential 1 yr Aluminum plate Brass Crossfire Burner LIFETIME This commenc...

Page 17: ...17 HMLS60 with LP or NG with Honeywell Electronic Spark Ignition System...

Page 18: ...18 DMSL60 with LP or NG with Dexan 3 Volt Battery or 110 Ignition System...

Page 19: ...19 MLS60 with LP or NG Regulator...

Page 20: ...20 System Tags and Markings...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Reviews: