1.3.3. Waste Gas (Flue) Leakages

If you smell flue gas!

•  Turn off the device.
•  Open the windows and doors.
•  Notify a trained and certified installer. Insufficient ventilation can cause 

toxic flue gas to escape. There is a risk of poisoning.

•  Never close or reduce the air inlet and outlet (vent) openings.
•  The device should not be operated until the reasons preventing the 

discharge of waste gas are eliminated.

•  Ensure that the ventilation pipes and flues are not damaged or clogged 

due to the danger caused by waste gases coming out.

•  Connect only one device to each ventilation system or flue outlet.
• The ventilation system pipes must not be connected to another air 

discharge duct.

•  Do not pass the flue system pipes through another air discharge duct.
•  Works on gas (gas line) components can only be carried out by a trained 

and certified installer due to the danger of explosion of flammable gases.

1.3.4. Combustion Air;

• Keep combustion air away from corrosive substances (halogenated 

hydrocarbons containing chlorine or fluorine compounds).

•  Never close the ventilation vents!

1.3.5. Inspection and Maintenance;

•  Maintenance and repairs may be carried out only by a trained and certified 

Warmhaus service.

•  Correct any installation errors immediately to avoid damage to the system.

1.3.6. Electrical Shock Hazard

Make sure that only an authorized electrician performs the 
electrical works. 

Before performing an electrical work, turn off the power and 
secure the unit against unintentional reconnection. Make sure that 
the system is disconnected from the electrical supply. 

1.3.7. Risk of Getting Scalded by Hot Water Faucet

When the water heater is running, the 
temperature may exceed 50 °C. To prevent 
such situations, the temperature in the tap 
should be limited by installing a thermostatic 
mixing valve. 

Heated water for washing laundry, dishes and other cleaning 
purposes can cause scalding and permanent injuries. 

Children, the elderly and the disabled are more likely to be 
permanently injured by hot water. Never leave such persons 
unattended in the bathtub or shower under any circumstances. 
Children should not be allowed to use the hot water taps themselves 
or fill a bathtub! 

1.3.8. Risk of Getting Injured by Flue Pipes

Avoid contact with the flue pipes. The temperature of the flue pipes can 
be up to 60 °C depending on the settings of the water heater and the hot 
season conditions. 

Summary of Contents for AQUWA 12

Page 1: ...GAS FUELED HERMETIC WATER HEATER USER MANUAL AQUWA 12...

Page 2: ...AquWa 12...

Page 3: ...Risk of Getting Injured by Flue Pipes 6 2 USER SECTION 8 2 1 GENERAL WARNINGS FOR USER 8 2 2 USE OF WATER HEATER 8 2 2 1 Control Panel and its Functions 8 2 2 2 Turning On Off of Water Heater and Temp...

Page 4: ...and application for LPG use should be performed by the company supplying the tank according to the local and legal rules 1 2 GENERAL WARRANTY CONDITIONS The manufacturer company shall not have any re...

Page 5: ...us service technician at least once a year Failure to follow these instructions may result in serious possibly fatal personal injury and also property and equipment damage It is strictly forbidden to...

Page 6: ...on and Maintenance Maintenance and repairs may be carried out only by a trained and certified Warmhaus service Correct any installation errors immediately to avoid damage to the system 1 3 6 Electrica...

Page 7: ...7 warmhaus com...

Page 8: ...ls while it is running Do not hold the heater with your hands or feet wet do not hold it without shoes and in bare feet Do not pull the electrical cables In case of damage to the cables turn off the w...

Page 9: ...Their Descriptions E 06 Lockout indicator Wiring error E 08 Ignition Combustion error indicator E 07 High limit protection E 41 Loss of flame 6 times in 10 minutes E 88 Gas valve operation malfunctio...

Page 10: ...from electrode or combustion Wear or rust on the electrode Electrode position Broken wiring Electronic card 1 Reset restart the device 2 If the malfunction persists call the Authorized Service E 09 N...

Page 11: ...1 Initial combustion lockout blocking problem Device is not functioning and E81 malfunction code is flashing on the screen Excessive blockage in the flue Combustion problem Incorrect flue Gas inlet pr...

Page 12: ...umption maximum m3 h 2 43 0 959 Nozzles 85 50 NOx Grade 6 6 NOx mg kWh 37 7 26 Hot water Load profile Load Profile L Seasonal Efficiency 77 Seasonal Efficiency Class Grade A Minimum Water Flow min 3 M...

Page 13: ...13 warmhaus com...

Page 14: ......

Page 15: ...been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject...

Page 16: ...AQUWA 12 User Manual 15011606000133 Revision Number Date R00 09 2021 GAS FUELED HERMETIC WATER HEATER USER MANUAL AQUWA 12...

Reviews: