background image

3

warmhaus.com

CONTENTS

1. 

DEAR WARMHAUS CUSTOMER  .....................................................................................................................4

1.1. 

GENERAL WARNINGS .............................................................................................................................................4

1.2. 

GENERAL WARRANTY CONDITIONS  ...................................................................................................................4

1.3. 

SAFETY INSTRUCTIONS  ......................................................................................................................................... 5

1.3.1.   Installation and Service .............................................................................................................................................................5
1.3.2.  Gas Leakages ...............................................................................................................................................................................5
1.3.3.  Waste Gas (Flue) Leakages .....................................................................................................................................................6
1.3.4.  Combustion Air; ..........................................................................................................................................................................6
1.3.5.  Inspection and Maintenance; ..................................................................................................................................................6
1.3.6.  Electrical Shock Hazard ............................................................................................................................................................6
1.3.7.  Risk of Getting Scalded by Hot Water Faucet ...................................................................................................................6
1.3.8.  Risk of Getting Injured by Flue Pipes ...................................................................................................................................6

2. 

USER SECTION ................................................................................................................................................8

2.1. 

GENERAL WARNINGS FOR USER .......................................................................................................................... 8

2.2. 

USE OF WATER HEATER  ........................................................................................................................................ 8

2.2.1.   Control Panel and its Functions .............................................................................................................................................8
2.2.2.   Turning On/Off of Water Heater and Temperature Setting  ..........................................................................................8
2.2.3.   Water Heater Standby Position  .............................................................................................................................................9

2.3. 

SAFETY FUNCTIONS ................................................................................................................................................9

2.3.1.   Malfunction/Error Codes Shown on the LCD Screen and Reset Their Descriptions ..............................................9
2.3.2.   Anti-Inertial Function  ...............................................................................................................................................................9
2.3.3.   Anti-Freeze Protection Function ............................................................................................................................................9
2.3.4.   Function of Operation with Solar Energy Systems with Storage  ...............................................................................9

2.4.  SOLUTIONS FOR MALFUNCTIONS AND ERRORS ............................................................................................. 10

3. 

TECHNICAL DATA  ..........................................................................................................................................12

Summary of Contents for AQUWA 12

Page 1: ...GAS FUELED HERMETIC WATER HEATER USER MANUAL AQUWA 12...

Page 2: ...AquWa 12...

Page 3: ...Risk of Getting Injured by Flue Pipes 6 2 USER SECTION 8 2 1 GENERAL WARNINGS FOR USER 8 2 2 USE OF WATER HEATER 8 2 2 1 Control Panel and its Functions 8 2 2 2 Turning On Off of Water Heater and Temp...

Page 4: ...and application for LPG use should be performed by the company supplying the tank according to the local and legal rules 1 2 GENERAL WARRANTY CONDITIONS The manufacturer company shall not have any re...

Page 5: ...us service technician at least once a year Failure to follow these instructions may result in serious possibly fatal personal injury and also property and equipment damage It is strictly forbidden to...

Page 6: ...on and Maintenance Maintenance and repairs may be carried out only by a trained and certified Warmhaus service Correct any installation errors immediately to avoid damage to the system 1 3 6 Electrica...

Page 7: ...7 warmhaus com...

Page 8: ...ls while it is running Do not hold the heater with your hands or feet wet do not hold it without shoes and in bare feet Do not pull the electrical cables In case of damage to the cables turn off the w...

Page 9: ...Their Descriptions E 06 Lockout indicator Wiring error E 08 Ignition Combustion error indicator E 07 High limit protection E 41 Loss of flame 6 times in 10 minutes E 88 Gas valve operation malfunctio...

Page 10: ...from electrode or combustion Wear or rust on the electrode Electrode position Broken wiring Electronic card 1 Reset restart the device 2 If the malfunction persists call the Authorized Service E 09 N...

Page 11: ...1 Initial combustion lockout blocking problem Device is not functioning and E81 malfunction code is flashing on the screen Excessive blockage in the flue Combustion problem Incorrect flue Gas inlet pr...

Page 12: ...umption maximum m3 h 2 43 0 959 Nozzles 85 50 NOx Grade 6 6 NOx mg kWh 37 7 26 Hot water Load profile Load Profile L Seasonal Efficiency 77 Seasonal Efficiency Class Grade A Minimum Water Flow min 3 M...