USER INSTRUCTIONS

Dual Thermostat

The  radiator  temperature  is  regulated  via  the 
boiler  control  thermostat.  The  thermostat  is  user 
adjustable from 55°C at its minimum setting (dial 
‘0’)  to  85°C  at  its  maximum  setting  (dial  ‘5’).  In 
order to provide an additional level of safety there 
is a high limit thermostat which has a cut off point 
of 0°C; this is factory set and is not adjustable. 
If thermostat trips it needs to be reset manually.

High Limit Thermostat Reset

If  the  high  level  thermostat  trip  has  operated, 
remove  the  reset  cover  by  using  a  coin  or 
screwdriver (turning anti clockwise) and press the 
small red button now exposed. Do not press the 
reset button while the boiler is still hot as this will 
cause damage to the thermostat.

Burner Lockout

When the pressure jet oil fired burner stops after 
failing to fire the red reset button will be illuminated. 
This  indicates  that  there  is  a  fault  or  there  is  no 
fuel getting to the burner. The house holder should 
only  reset  the  burner  twice  in  succession.  If  the 
burner continues to lockout contact Warmflow or 
your service engineer.

System Pressure – System & Combi Boilers

When the boiler is connected to a sealed system 
the  system  pressure  should  be  periodically 
checked. The minimum pressure, as indicated by 
the black needle, is 0.5 bar when the boiler is cold 
and 2.5 bar when the boiler is at normal operating 
temperature. If the pressure is outside this range 
contact Warmflow or your installer.

Control Thermostat

High

Limit

Reset

Reset

Burner Lock Out Reset

System Pressure

Summary of Contents for U Series

Page 1: ...ency Condensing Boilers Models covered by this manual U Series Utility U70HE U90HE U120HE Utility Pumped UP70HE UP90HE Utility System US70HE US90HE Utility Combi UC70HE UC90HE K Series Kabin Pak K70HE...

Page 2: ...ance Telephone 0870 240 6532 Fax 028 9262 2827 Email service warmflow co uk Web www warmflow co uk For Parts Service Technical Warranty Contact Great Britain N Ireland Tel 0870 240 6532 Republic of Ir...

Page 3: ...Gravity System 39 4 2 Two Pipe System 40 4 3 De aerator System 40 4 4 One Pipe Lift System 41 5 0 Flues 5 1 Installation of Balanced Flues 42 5 2 Conventional Flues 44 5 3 Flue Terminal Positions 44 6...

Page 4: ...hile the boiler is still hot as this will cause damage to the thermostat Burner Lockout When the pressure jet oil fired burner stops after failing to fire the red reset button will be illuminated This...

Page 5: ...which has a cut off point of 110 C this is factory set and is not adjustable The high limit thermostat is located under the control panel to the left hand side press button to reset As standard the p...

Page 6: ...dinary plastic pipe eg plastic overflow pipe directly into the household drain or soak away Any blockage in the drain could lead to an alteration in the combustion settings because of partially blocke...

Page 7: ...ust be fitted with a suitable chemical scale preventer eg Fernox Quantomat or Combimate alternatively contact Warmflow for further details 5 That the flow from any one hot water outlet does not exceed...

Page 8: ...cturer s guarantees are void if the appliance is not installed and commissioned in accordance with the recommendations made herein 1 2 General Requirements The installation of the boiler must be in ac...

Page 9: ...duced even if the heat store is up to temperature 1 3 1 Pump Over Run Where there is a build up of excess heat in the boiler primary heat exchanger and the central heating has not been selected then t...

Page 10: ...emovable 1 5 2 U Series Utility Pre Wired UHE Key Components 1 Heat Exchanger 2 Condensing Unit 3 Auto Air Vent 4 Service Door 5 Dual Safe Thermostat 6 Heat Exchanger Baffles 7 Service Door 8 Service...

Page 11: ...t 10 Heat Exchanger Baffles 11 Service Door 12 Service Door Cover 13 Condensate Trap 14 Riello RDB 2 2 Burner 15 Heating Flow Connection 16 Heating Return Connection 1 5 4 U Series Utility System USHE...

Page 12: ...or 10 Service Door Cover 11 Control Panel 12 Expansion Vessel 13 Riello RDB 2 2 Burner 14 Heat Exchanger Baffles see dimension drawing for details of connections 1 5 6 U Series Utility Combi UCHE Cont...

Page 13: ...s Kabin Pak Casing Components 1 Boiler Assembly 2 Top Casing removable 3 Flue Assembly removable 4 Rear Flue Casing 5 Blanking Plug removable 6 Rear Casing removable 7 Side Casing 8 Front Casing remov...

Page 14: ...n 12 Heating Return Connection 1 5 9 K Series Kabin Pak Pumped KPHE Key Components 1 Heat Exchanger 2 Condensing Unit 3 Pipework Assembly 4 Pressure Relief Valve 5 Auto Air Vent 6 Circulating Pump 7 A...

Page 15: ...1 5 11 K Series Kabin Pak Combi KCHE Key Components 1 Heat Exchanger 2 Heat Store 3 Condensing Unit 4 Service Door 5 Pipework Assembly 6 Plate Heat Exchanger 7 Twin Head Pump 8 Condensate Trap 9 Servi...

Page 16: ...2 K Series Kabin Pak Combi KCHE Control Panel Control Thermostat Mains On Lamp Green High Limit Tripped Lamp Yellow Burner Lockout Lamp Red HW On Off Switch CW On Off Switch High Limit Thermostat Rese...

Page 17: ...ted CH Pump Only Runs Room Stat Satisfied Boiler Stat Satisfied Boiler Limit Stat Tripped Burner Fires DHW Pump Only Runs HW Limit Stat Satisfied Boiler Limit Stat Tripped Burner Fires Burner Stops Pr...

Page 18: ...583 50 75 86 134 21 Q P N M L K J H G F E D C B A MODEL R S UC 596 865 601 766 134 207 390 841 817 840 845 74 115 167 205 310 666 2 2 Dimensions 2 2 1 U Series Utility UHE UPHE USHE Models 2 2 2 U Ser...

Page 19: ...00 700 773 210 95 161 67 40 90 40 67 705 50 50 KP 413 900 700 773 210 95 161 67 40 90 40 67 705 50 50 KS 413 900 700 773 210 95 161 67 40 90 40 67 705 50 50 Q P N M L K J H G F E D C B A MODEL R S KC...

Page 20: ...Page 18 2 3 Flue Options Components Dimensions 2 3 1 HE Low Level Balanced Flue Kit FBF Comprising the following four main components...

Reviews: