COMMISSIONING INSTRUCTIONS
TR05A140.B1107
39
Parameters 8 through 13
Not applicable to this appliance
Parameter 14 – Burner type
Access the parameters menu as described in Section 5.7.1.
Use the
&
buttons to adjust the parameter value:
00 = Atmospheric burner (all outputs);
01 = Premix burner – 25 kW;
02 = Premix burner – 29-34 kW;
03 = Premix burner – 50 kW;
Press and release the
S
button.
The parameter number (14) will appear on the display.
To store your changes, switch the appliance off then on again using
the
ON/OFF
button.
Parameters 15 and 16
Not applicable to this appliance
S
S
14
02
01