WARMSOURCE INSTALLATION
Securing Warmsource
f
Double check code clearances and recommended
minimum clearance dimensions (pg. 7)
f
Fasten the mounting bracket to the wall (the use
of two, 2"x 4" x 18" wood sleepers may be necessary.
Securely fasten the sleepers to the wall studs,
then mount the bracket to the sleepers)
f
Once the bracket is secured, use the lifting handles
to place Warmsource on to the mounting bracket
(the unit is very heavy and requires two individuals
to move safely)
Connections
f
Connect the PVC intake and exhaust lines, gas line,
condensation discharge line and pressure relief
discharge line per the Lochnivar Noble Manual
f
Plumb the cold water line to the backflow
preventer and the pressure reducing valve
(WCS Design Drawings)
f
Install all 1
1/4
" copper plumbing and primary
distribution lines
f
Install the condensate neutralizer (Lochnivar Noble
Manual, pg. 58). If installing vertically instead
of horizontally be sure to confirm the correct
orientation (illustration)
To Warmsource
Water Flow
Condensate Drain
To Drain
Overflow Bypass
Warmsource is very heavy and will require two
people to lift and carry.