Backlight display
6
—
Adjust displayed temperature to
suit personal needs
(calibration)
7
Proportional
output
and
constant temperature output
8
Select the control accuracy (it is
only valid with the HP control
mode)
9
Valve-protect function
1)
Select maximum temperature set point
This feature provides a maximum set point temperature. The default setting is
35
℃
, and it can be changed between 20
℃
to 35
℃
.
2)
Select minimum temperature set point.
This feature provides a minimum set point temperature. The default setting is 5
℃
,
It can be changed between 5
℃
to 20
℃
.
3)
Select ECO setting temperature
Economy Temperature used for energy saving periods e.g. during the night ( )
4)
Select comfort setting temperature
Comfort Temperature used for comfort periods e.g. during the morning/after work
(
)
5)
Backlight display
To either have the backlight display on or off.
6)
Adjust displayed temperature to suit personal needs
You can adjust the room temperature display up to 5 degrees higher or lower. This
works well to calibrate to either infrared heating panels or in accordance with other
room thermostats present. The current or adjusted room temperature will be displayed
on the right side of the display.
7)
Select control mode for system
Proportion output is meant for living environments, the room temperature will
always be increased or decreased subtly making the user feel comfortable, neither too
cool or too hot.
Constant temperature on/off output between -0.5
℃
to 0.5
℃
.
8)
Select the control accuracy reading
It is for screen display of the temperature accuracy (it is only valid on the HP control
mode). The factory default setting is 0.5
℃
.
9)
Valve-protect function
Function about valve Anti-blocking, it is used for protecting valve, if no output more
than 24 hours, it will be forced to open 30s.
/
/
—
/