6. Immerse approximately 3/4 of the length of the stainless steel portion in a 

container of the sanitizing solution and run for two (2) minutes on High.

7. dO nOt rInSe after SanItIZIng IS COMpLete. Allow to air 

dry before use.

nOte

dO nOt IMMerSe pLaStIC HOuSIng In WaSHIng 

SOLutIOn, rInSe Water, Or SanItIZIng SOLutIOn. 

preVent LIQuId frOM runnIng IntO pLaStIC HOuSIng 

BY WrIngIng aLL eXCeSS MOISture frOM CLOtHS Or 

SpOngeS BefOre uSIng tHeM.

WarrantY – 

LIMIted One Year WarrantY

Waring warrants every new WARING

®

 COMMERCIAL PRODUCT to be 

free from defects in material and workmanship for a period of 1 year from the 

date of purchase when used with foodstuffs, nonabrasive liquids (other than 

detergents) and nonabrasive semi-liquids, proving it has not been subjected to 

loads in excess of the indicated rating.
 Under this warranty, Waring

®

 Commercial will repair or replace any part which, 

upon examination, appears to us to be defective in materials or workmanship, pro-

vided the unit is delivered prepaid to the Waring Service Center at 314 Ella T. 

Grasso Avenue, Torrington, CT 06790, or any Authorized Service Center.
 This warranty does not: a) apply to any unit which has become worn, defective, 

damaged or broken due to misuse, repairs, or servicing by other than the Waring 

Service Center or an Authorized Service Center or due to abuse, misuse, over-

loading or tampering; b) cover consequential damages of any kind.
This warranty gives you specific legal rights, and you may have other rights 

which vary from state to state so that certain limitations or exclusions set forth 

above may not apply to you.
 WARNING -  This warranty is VOID if the appliance is used on Direct 

Current  (D.C.)

SerVICe

Refer to the list of Authorized Service Centers enclosed with your Waring

®

 

Commercial Product for the name of the nearest Service Center, or Contact 

Waring in one of the following 3 ways:

 

1)   Mail:

 

  WARING Service Center,  

 

  314 Ella T. Grasso Ave.  

 

  Torrington, CT 06790 USA

 

2)  Phone Product Service:  

 

  (800) 4WARING OR (800) 492-7464

  3)  Internet:   http://www.waringproducts.com

    E-mail: [email protected]
 

Ship units for repair to the above address or to an 

Authorized Service Center. Do not ship to a Waring 

Sales Office.

CLeanIng InStruCtIOnS

tHe QuIK StIK

®

 IMMerSIOn BLender MuSt Be 

CLeaned and drIed aCCOrdIng tO tHe fOLLOWIng 

InStruCtIOnS after eaCH uSe.  

for food Service applications

•  Wash, rinse, and sanitize the stainless steel portion of the Quik Stik

®

 prior 

to initial use, after each use, or whenever it will not be used again within a 

period of 1 hour.

•  Clean and sanitize the plastic motor housing prior to initial use and after 

each use.

•  Washing solutions based on non-sudsing detergents, and chlorine-based  

sanitizing solutions having a minimum chloride concentration of 100 PPM 

are recommended.

The following washing, rinsing, and sanitizing solutions, or their equivalents, 

may be used.
 

 

dILutIOn 

SOLutIOn  prOduCt 

In Water  teMperature

Washing 

Diversey Wyandotte  4 Tbls./Gallon  Hot 115°F (46°C)   

 

Diversol BX/A 

 

Or CX/A 

Rinsing 

 

Plain Water 

Warm 95°F (35°C)

Sanitizing 

Clorox Institutional  1 Tbl./Gallon  Cold 50-70°F (10°-21°C) 

 

Bleach

• In repetitive use applications, frequent cleaning will prolong life.
to wash and sanitize the Quik Stik

®

:

1. Rinse the exterior and interior stainless steel portion of the Quik Stik

®

  

under running water.  Scrub and flush the exterior and interior stainless 

steel portion to dislodge and remove as much food residue as possible.

2. Wipe down the exterior of the plastic housing and the stainless steel  

portion of the Quik Stik

®

 with a soft cloth or sponge dampened with  

the washing solution.

3. Immerse approximately 3/4 of the length of the stainless steel portion in  

a container of the washing solution and run for two (2) minutes on High.

4. Repeat steps two (2) and three (3) using clean rinse water in place of the 

washing solution.

nOte - IMpOrtant

In Order tO MInIMIZe tHe pOSSIBILItY Of SCaLdIng, 

teMperature Of tHe WaSHIng SOLutIOn and rInSe 

Water MuSt nOt eXCeed 115°f (46°C).
5. Wipe down the exterior of the plastic housing and the stainless steel  

portion of the Quik Stik

®

 with a soft cloth or sponge dampened with  

the sanitizing solution.