Waring 6001C IB Instructions Manual Download Page 5

5

  • 

 Clean and sanitize motor base prior to initial use and  

after each use.

  •    Washing solutions based on non-sudsing detergents and 

chlorine-based sanitizing solutions having a minimum chlorine 

concentration of 100 PPM are recommended.

The following washing, rinsing, and sanitizing solutions, or their 

equivalents, may be used.

To Sanitize and Dry Container:

  1.   Wipe down exterior of juicing assembly with a soft cloth or 

sponge dampened with sanitizing solution.

  2.   Submerge removable components in sanitizing solution  

for two (2) minutes.

  3.  Do not rinse juicing assembly after sanitizing is completed.
  4.  Allow parts to air-dry.

To Clean and Sanitize Motor Base:

  1.   UNPLUG POWER CORD. Wipe down exterior surfaces of motor 

base with soft cloths or sponges dampened with washing 

solution, rinse water, and sanitizing solution. Prevent liquid from 

running into motor base by wringing all excess moisture from 

cloths or sponges before using them.

     DO NOT IMMERSE MOTOR BASE IN WASHING SOLUTION, 

RINSE WATER OR SANITIZING SOLUTION.

   2.   Allow motor base to air-dry before using.

Any other servicing should be performed by an authorized service 

representative.

  SOLUTION 

PRODUCT 

DILUTION IN WATER 

TEMPERATURE

  WASHING 

DIVERSEY

®

 WYANDOTTE 

4 TABLESPOON 

HOT 115°F (46°C) 

 DIVERSOL

®

 BX/A OR CX/A 

/ GALLON 

  RINSING 

PLAIN WATER 

 

WARM 95°F (35°C)

  SANITIZING 

CLOROX

®

 

1 TABLESPOON / GALLON 

COLD 50°F –70°F 

 INSTITUTIONAL 

BLEACH  

(10°C–21°C)

Reviews: