Warehouse of Tiffany CFL-8111 Use And Care Manual Download Page 2

Table of Contents 

Safety Information 

Hanging the Fan 

Pre-Installation 

Attaching the Fan Blades 

HARDWARE INCLUDED 

Attaching the Lights 

Ceiling 

Install the crystal shade 

Use of remote control 

Care  and  cleaning 

Safety Information 

1,  To reduce the risk  or  electric shock  the  electricity  has 

been turned off at the circuit breaker or fuse box before 

begin. 

2,  All wiring must be in accordance with the National Electrical 

Code NASVNFPA 70-1999  and  local  electrical codes. 

Electrical installion should  be performed by  a qualified 

licensed electrician . 

3,  Tne outlet box and support structure must  be  securely 

mounted and capable of reliably supporting 35 ibs. (15.9 

kg). Use only UL Listed outlet boxes marked "Acceptable 

for Fan Support of 35 ibs. (15.9 kg) or less." 

4,  The fan must be mounted with a minimum of 7 ft. (2m) 

clearance from the trailing edge of the blades to the floor. 

5,  Do not operate the reversing switch while the fan blades 

are in motion. You must turn the fan  off  and  stop  the 

blades before you reverse the blade direction. 

6,  Do not place objects in the path of the blades. 

7,  To avoid personal injury or damage to the fan and other 

items.use caution when working around or cleaning the 

fan. 

8,  Electrical diagrams are for reference only. Light kits  that 

are not packed with the fan must be UL-listed and marked 

suitable for use with the model  fan  you  are  installing. 

Switches must be UL General Use Switches. Refer to the 

instructions packaged with the light kits and switches for 

proper assembly. 

9,  After making electrical connections, spliced conductors 

should be turned upward and pushed  carefully up into 

tne outlet box.The wires should be spread apart with the 

grounded  conductor  and  the  equipment-grounding 

conductor on one side of the outlet box. 

10,  All setscrews must be checked and retightened where 

necessary before installation. 

10 

11 

WARNING:TO 

reduce the risk of personal injury, 

do not bend the blade brackets (also referred to as 

flanges) during assembly or after installation.Do not 

insert objects in the path of the blades . 

WARNING: 

Remove the rubber motor stops on 

the bottom of the fan before installing the blades 

or testing the motor. 

WARNING: 

To reduce the risk or fire or electric 

shock,do not use this fan with any solid-state 

speed control device. 

WARNING:To 

avoid possible electrical shock, 

turn the electricity off at the main fuse box before 

wiring.It you feel you do not have enough electrical 

wiring knowledge or experience, contact a licensed 

electrician. 

WARNING: 

Electrical diagrams are for reference 

only. Optional use of any light kit shall be UL-listed 

and marked suitable for use with this fan. 

WARNING: 

To reduce the risk of fire, electric shock, 

or personal  injury. mount to outlet box marked" 

Acceptable for fan support of 35 ibs.(15.9 kg)or 

less." and use the screws provided with the outlet 

box. 

Summary of Contents for CFL-8111

Page 1: ...USE AND CARE GUIDE 52 INCH CRYSTAL CEILING FAN...

Page 2: ...marked suitable for use with the model fan you are installing Switches must be UL General Use Switches Refer to the instructions packaged with the light kits and switches for proper assembly 9 After...

Page 3: ...der the warranty invalid There is no other sxpress warranty hereby di sclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the e...

Page 4: ...er BB Plastic wire nut not to scale cc Blade arm screw and lock washer DD Pull chain and fob not to scale hand pull chain only EE Mounting screws FF Expansion Bolts GG Balanced parts package remote co...

Page 5: ...rding to actual requirements of the customers ffi Note According to the ceiling of different materials use different screws to fix the hanging bracket Don t fix the hanging bracket on the wood ceiling...

Page 6: ...54 in Lead wires for use with an extended ball downrod assembly If using the 4 5 in ball downrod assembly B provided youcan cut the lead wires to your desired length no shorter than 12 in 1 BLACK t 7...

Page 7: ...move the rubber motor stops on the bottom of Ll 1 the fan before installing the blades or testing the motor I NOTE Your fan features revolutionary advancements for quick and easy blade installation In...

Page 8: ...hite line of the light and tie insulated rubber tape 2 lnsert the blue line in the switching box of the motor into the blue line of the light and tie insulated rubber tape Assembly Attaching the Light...

Page 9: ...an pull chain controls the fan speed as follows 1 pull High 2 pulls Medium 3 pulls Low 4 pulls off The appropriate speed settings for warm or cool weather depends on factors such as the room size ceil...

Page 10: ...LIGHT NO OFF II8 Auto off after 1 hr Auto off after 2hr 11B Auto off after 4hr Auto off after 8hr From controller remote control ONLY remote control ONLY FOR AC INL FOR AC INN remote control ONLY SWI...

Page 11: ...witch housing Ensure allmotorhousing screws are snug Ensure the screws that attach the fan blade bracket to the motor hub are tight Ensure the wire nut connetions are not ratting against each other or...