WAPRO WAGATE KVI 110 Installation & Maintenance Download Page 4

4

STORAGE 

The product must be stored in a dry, well-ventilated environment, away from direct sunlight. Temperatures in storage 

must be between -30°C and 40°C. The surface temperature of the plastics can´t exceed 80°C. 

The product must not be flooded or otherwise submerged in water during storage. 

If the product is stored outside for longer durations, it is advisable to cover up the inlet pipe to keep dirt and debris out, 

as well as keeping wildlife from inhabiting the flap valve.   

In areas with high humidity or with big fluctuations in temperature, the transportation wrapping must be removed to 

avoid buildup of condensation. 

IDENTIFICATION 

Do not remove the label. If purchasing spare parts, state the size and type of valve.

FLAP VALVE APPLICATIONS

The following table shows the applicable uses of each flap valve type, as well as which types of operation is available. If a 

flap valve is used outside its intended application, proper function can´t be ensured, contact Wapro for advice. 

WAFLAP

TM

 FLAP VALVES [DN/OD] / [NPS/OD]

Made in Denmark

wapro.com

KVM

KVT

IKV
IKF

KVR

KVD
KVI
KVB
KVF

125/5”
225/9”
450/18”
630/25”
900/36”

160/8”
250/10”
500/20”
700/28”
1000/40”

180/8”
280/11”
560/22”
710/28”
1100/44”

110/4”
200/8”
400/16”
600/24”
800/32”
1200/48”

®

MODEL

PIPE

WALL

FOR 

BENCHING 

MANHOLES

TYPE OF 

MOUNTING

DESCRIPTION

KVR

X

(X)

Mirror 

welding 

Mirror welding for pipe end

KVF

X

Wall

Mounting on flat wall

KVM

X

Coupling

Mounting on pipe end

KDV

X

Flenge

Standardly produced with flanges according to 

EN1092-1. Other flange sizes available upon request

KVI

X

(X)

Insert

For insert in existing pipes. ID must be provided

KVB

X

Rounded

Mounting on round walls and wells

KKL

X

Wall

Mounting on flat wall

IKV

X

X

Insert

Installation in plastic well

IKF

X

X

Insert

Installation in PVC and / or concrete inspection wells, 

equipped with a float

KVI-B

X

Insert

For insert into concrete pipes

(X) = is possible

Summary of Contents for WAGATE KVI 110

Page 1: ...INSTALLATION MAINTENANCE PRODUCT GUARANTEE WAGATE FLAP GATES PLEASE NOTE SERIAL ORDERNUMBER HERE...

Page 2: ...U FOR PURCHASING A WAPRO PRODUCT FOR FURTHER PRODUCT INFORMATION PLEASE REFER TO WAPRO COM INDEX OPERATION INSTRUCTIONS 3 TRANSPORT AND STORAGE 3 STORAGE 4 MOUNTING 5 6 COMMISSIONING 7 MAINTENANCE 7 W...

Page 3: ...of any damage obtained during transport or storage Prior to first use the user needs to make sure that the steps described in the commissioning part of the manual have been followed precisely TRANSPO...

Page 4: ...ch types of operation is available If a flap valve is used outside its intended application proper function can t be ensured contact Wapro for advice WAFLAPTM FLAP VALVES DN OD NPS OD Made in Denmark...

Page 5: ...ased separately and follow the instructions for installation that are included Make sure to bolt through all mounting holes When mounted the flap valve should not lean more than 5 degrees from horizon...

Page 6: ...on Violating this can result in reduced watertightness blockage of moving parts and permanent damage to the flap valve IKV and IKF flap valve for direct plug in into pipe installations are supplied as...

Page 7: ...sed by other equipment To request warranty service the buyer should contact the WaGate dealer where the valve was purchased within a reasonable time after discovering any defects The valve serial numb...

Page 8: ...Rev 1 0 CONTACT WAPRO customerservice wapro com wapro com SE 46 0 454 185 10 DK 45 64 82 40 00 US 1 888 927 8677 UK 44 114 308 0123...