Picture 3
6. Troubleshooting
1, the status on light’s indication
RUN: green, normal work light.
ERR: red, failure light, the motor with phase short-circuit, overvoltage and under-voltage
protection.
2 Troubles
Alarm indicator
Causes
Measures
LED off turn
Wrong connection for power
Check wiring of power
Low-voltages for power
Enlarge voltage of power
Motor doesn’t run, without
holding torque
Wrong connection of stepper
motor
Correct its wiring
Summary of Contents for DQ542MA