background image

 

Tripod BO-DSN10 

www.wano.pl 

 

After turning off the memory function, swiped multiple cards only the last swipe card is valid, allowing only 
one person to pass. (Default is 0, turn off the memory function) 
 

5.

 

"F05"

 

Repeated gate opening and closing test, mainly used to test the stability and aging of the gate control board. 
In the test mode, press the 

MENU

 key to exit the test. 

 

6.

 

"F06"   

Zero signal setting. (Default is 0, recommended to change to 1) 

0:

 Immediately close the gate when the Zero signal is detected (used on the old tripod turnstile movement) 

1:

  The zero signal is detected, wait for the zero signal to disappear before closing the gate. (New tripod 

turnstile, full-height turnstile movement, recommended to set it to 1, in case the passage speed is slow and 
may be stuck) 
 

7.

 

"F07"   

Constant opening setting for the gate, in seconds. (Default is 0, turn off the constant opening function) 
For example, if the constant opening is set to 3 seconds, when the gate opening signal is continuous and lasts 
for more than 3 seconds, the gate will remain open, allowing continuous passage until the continuous 
opening signal is disconnected, and then the gate will close. 
 

8.

 

"F08"   

Gate opening delay, in seconds. (Default is 1, delay of 1 second) 
This parameter is effective only when the memory function is enabled. After the memory function is turned 
on, during continuous passage of multiple people, there will be a pause of 1 second before the gate opens 
again. This function prevents the gate from opening while the previous person has not passed through the 
passage. 
 

9.

 

"F09"   

Limit switch count setting. (Default is 1) 
Set a limit signal to be detected several times during the opening process before closing the gate, in most 
cases it is set to 1. 
For example, if set to 3, one gate opening signal can allow passage for 3 people in a row. 

 

10.

 

"F10" 

Reset. After the display screen shows the letters "SYS", press the 

MENU

 key again to confirm and apply the 

reset. 
 

11.

 

"F11" 

Exit the menu. Or automatically exit if there is no key operation within 5 seconds. 
 

 

 
 

Summary of Contents for Tripod BO-DSN10

Page 1: ...lease read and follow the installation instructions before operating the equipment and keep the instructions for future reference or use after debugging Tripod BO DSN10 Last update Aug 2023 User Manua...

Page 2: ...system 3 3 Install Instruction 4 3 1 Installation note suggestion 4 3 2 Turnstile circuit board wiring diagram 5 6 4 Menu Parameter Setting 6 4 1 Button introduction 6 7 4 2 Menu setting 7 4 3 Paramet...

Page 3: ...hese signals and then issues execution commands to the direction indicator light motor counter and alarm Direction indicator light display the current status of the passage signs and guide pedestrians...

Page 4: ...and embed the anchor bolt or expansion bolt of M12 11 Open the case select one of the equipment as the reference preferably choose the middle one as the reference align the base bolt hole with the co...

Page 5: ...board wiring diagram Turnstile electrical parts area with power supply port please connect to 110V 220V electrical power supply Turnstile circuit board with port OP L COM OP R it can be connected to a...

Page 6: ...y MENU key 1 It functions as the menu key on the standby interface long press this key to enter the menu 2 In the menu interface it functions as the confirmation key after selecting the corresponding...

Page 7: ...to manually exit the menu Or if there is no key operation for 5 seconds it will automatically exit the menu 4 3 Parameter setting instruction After the control board is powered on the LED screen displ...

Page 8: ...opening is set to 3 seconds when the gate opening signal is continuous and lasts for more than 3 seconds the gate will remain open allowing continuous passage until the continuous opening signal is di...

Page 9: ...valve terminal of the main board and judge whether the solenoid valve is damaged B Tripod turnstile arms won t fall down when power off a check if the electromagnet pole drop support is loose readjust...

Page 10: ...www wano pl 10 We are very happy to help you in the future when you encounter problems or product defects if the use or operation is not clear please timely contact the after sales service staff 6 Cu...