Tripod BO-DSN10
www.wano.pl
8
After turning off the memory function, swiped multiple cards only the last swipe card is valid, allowing only
one person to pass. (Default is 0, turn off the memory function)
5.
"F05"
Repeated gate opening and closing test, mainly used to test the stability and aging of the gate control board.
In the test mode, press the
MENU
key to exit the test.
6.
"F06"
Zero signal setting. (Default is 0, recommended to change to 1)
0:
Immediately close the gate when the Zero signal is detected (used on the old tripod turnstile movement)
1:
The zero signal is detected, wait for the zero signal to disappear before closing the gate. (New tripod
turnstile, full-height turnstile movement, recommended to set it to 1, in case the passage speed is slow and
may be stuck)
7.
"F07"
Constant opening setting for the gate, in seconds. (Default is 0, turn off the constant opening function)
For example, if the constant opening is set to 3 seconds, when the gate opening signal is continuous and lasts
for more than 3 seconds, the gate will remain open, allowing continuous passage until the continuous
opening signal is disconnected, and then the gate will close.
8.
"F08"
Gate opening delay, in seconds. (Default is 1, delay of 1 second)
This parameter is effective only when the memory function is enabled. After the memory function is turned
on, during continuous passage of multiple people, there will be a pause of 1 second before the gate opens
again. This function prevents the gate from opening while the previous person has not passed through the
passage.
9.
"F09"
Limit switch count setting. (Default is 1)
Set a limit signal to be detected several times during the opening process before closing the gate, in most
cases it is set to 1.
For example, if set to 3, one gate opening signal can allow passage for 3 people in a row.
10.
"F10"
Reset. After the display screen shows the letters "SYS", press the
MENU
key again to confirm and apply the
reset.
11.
"F11"
Exit the menu. Or automatically exit if there is no key operation within 5 seconds.