Limited Warranty

Wanner Engineering, Inc. extends to the original purchaser 

of equipment manufactured by it and bearing its name, a 

limited one-year warranty from the date of purchase against 

defects  in  material  or  workmanship,  provided  that  the 

equipment is installed and operated in accordance with the 

recommendations and instructions of Wanner Engineering, 

Inc. Wanner Engineering, Inc. will repair or replace, at its 

option,  defective  parts  without  charge  if  such  parts  are 

returned with transportation charges prepaid to Wanner 

Engineering,  Inc.,  1204  Chestnut  Avenue,  Minneapolis, 

Minnesota  55403.
This warranty does not cover:
1.  The  electric  motors  (if  any),  which  are  covered  by 

the  separate  warranties  of  the  manufacturers  of  these 

components.
2. Normal wear and/or damage caused by or related to 

abrasion,  corrosion,  abuse,  negligence,  accident,  faulty 

installation or tampering in a manner which impairs normal 

operation.
3. Transportation costs.
This  limited  warranty  is  exclusive,  and  is  in  lieu  of  any 

other warranties (express or implied) including warranty 

of  merchantability  or  warranty  of  fitness  for  a  particular 

purpose  and  of  any  noncontractual  liabilities  including 

product  liabilities  based  on  negligence  or  strict  liability. 

Every  form  of  liability  for  direct,  special,  incidental  or 

consequential  damages  or  loss  is  expressly  excluded 

and denied.

Warranty

Summary of Contents for STAN-COR MK Series

Page 1: ...trifugal Pumps W0469 Installation and Operation Manual SCM 991 2400A WANNER ENGINEERING INC 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 68...

Page 2: ...receipt of your WANNER MK pump verify 1 The equipment has not been damaged in transit 2 The pump model number and serial number are stamped on the nameplate Model Serial No Explanation of Symbols Wor...

Page 3: ...00 76 2 4 72 119 9 6 22 158 6 22 158 W0471 1 Discharge Flange 1 2 13 Threaded Inserts on 3 1 8 BC 4 Places ANSI Class 150 FF 1 1 2 Sunction Flange 1 2 13 Inset Bolts on 3 7 8 BC 4 Places ANSI Class 1...

Page 4: ...nner Magnet 9 Wear Ring Outer Rear 10 Wear Ring Inner Rear 11 Wear Ring Outer Front 12 Wear Ring Inner Front 13 Thrust Washer Front 14 Bearing Forward 15 Bearing Rear 16 Spacer Bearing 17 Shaft 18 O r...

Page 5: ...Rear SC 1 16 105S001 Spacer Bearing Kynar 1 17 060S003 Shaft SC 1 Ref No Part Number Description Qty Pump Ref No Part Number Description Qty Pump 18 530S003 1 O ring Containment Shell Viton 1 530S003...

Page 6: ...g a pressure gage in the discharge piping 7 Clean piping as necessary to remove dirt grit weld slag etc 8 Provide clearance behind motor to remove motor and outer magnet 24 approximately 2 feet 9 For...

Page 7: ...sassembly Work Safety Magnetic drive pumps contain strong magnets which pose risk to people and property Based on this the following must be observed 1 Individuals with cardiac pacemakers should avoid...

Page 8: ...e 3 8 hex nuts inserted in the bottom rear half of case support 20 4 Remove hex bolts 28 29 and then remove the front half of case support 20 5 Insert two flat screw drivers 180 from each other betwee...

Page 9: ...an be removed with the inner magnet attached 10 Remove inner rear wear ring 10 from impeller 7 Figure 4 Figure 5 Figure 6 6 Remove inner magnet and impeller assembly from pump 7 If the inner magnet 8...

Page 10: ...ol 6 Install stator 19 into containment can 6 with counter clockwise rotation left hand thread 7 Install outer rear wear ring 9 into lock pockets and rotate counter clockwise Heat stake in three place...

Page 11: ...ess ring onto the impeller and rotate clockwise to lock If the fit is not tight heat stake the ring to the impeller in three places Remove any raised plastic from heat staking process 13 Assemble inne...

Page 12: ...16 Figure 17 17 Install assembled inner magnet and impeller assembly onto shaft and lower gently into containment can 21 Carefully install case 1 over shaft carefully and onto containment can Press f...

Page 13: ...all case bolts are tight then fully tighten discharge flange support bolts 35 37 Lubricate O ring 5 inside of the suction flange 4 and install suction flange support 38 Guide assembled pump module ove...

Page 14: ...o rotation and restart pump NPSH problems Inlet pressure too low Verify suction pipe is not too long Insufficient Discharge Insufficient flow Fully open suction valves Clogged strainer Clean strainer...

Page 15: ...aid to Wanner Engineering Inc 1204 Chestnut Avenue Minneapolis Minnesota 55403 This warranty does not cover 1 The electric motors if any which are covered by the separate warranties of the manufacture...

Page 16: ...1 Fax 612 332 6937 SCM 991 2400A WANNER ENGINEERING INC 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www stancorpump com email sales w...

Reviews: