background image

Wanner Engineering, Inc.

14

United States 

Instant Information:   www.stancorpump.com

(61) 33-5681   Fax (61) 33-6937 

 SCM-991-400A

Problem 

Possible Cause 

Remedy 

Pump Does Not Prime

 

Fluid not reaching pump 

Verify suction pipe is submerged   

 

 

 

Open suction valve 

 

 

Wrong direction of rotation 

Reverse motor leads 

 

No Discharge

 

Valves closed 

Verify valves are open 

 

 

Bypass valve open 

Adjust by pass valve 

 

 

Air leak in suction 

Tighten connections 

 

 

Apply sealant to all threads 

 

 

Verify suction pipe is submerged   

 

Clogged strainer 

Clean strainer 

 

 

Pump is worn 

Rebuild pump 

 

 

Magnetic coupling broken free 

Stop pump. Wait until there is no rotation and  

 

 

restart pump 

 

 

NPSH problems 

 

 

Inlet pressure too low 

Verify suction pipe is not too long   

Insufficient Discharge

 

Insufficient flow 

Fully open suction valves   

 

Clogged strainer 

Clean strainer 

 

 

Speed too low 

Increase driver speed if possible   

 

Pump not sized to application 

A larger pump may be required 

 

 

Bypass valve open 

Adjust bypass valve 

 

 

Pump worn 

Rebuild pump 

 

Loss of Suction After

 

Change in fluid properties 

Verify fluid properties 

 

Satisfactory Operation

 

Air leak in suction 

Tighten connections 

 

 

 

Verify suction pipe is submerged   

Excessive Power

 

Head lower than rated 

Reduce flow 

 

Consumption

 

Liquid to heavy 

Check specific gravity and viscosity 

 

Worn or damaged parts 

Service unit 

 

Rapid Pump Wear

 

Abrasives in fluid 

 

 

Erosion

 

Materials of construction not  

 

suitable for fluid being pumped

Troubleshooting

Summary of Contents for STAN-COR MK Series

Page 1: ...trifugal Pumps W0469 Installation and Operation Manual SCM 991 2400A WANNER ENGINEERING INC 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 68...

Page 2: ...receipt of your WANNER MK pump verify 1 The equipment has not been damaged in transit 2 The pump model number and serial number are stamped on the nameplate Model Serial No Explanation of Symbols Wor...

Page 3: ...00 76 2 4 72 119 9 6 22 158 6 22 158 W0471 1 Discharge Flange 1 2 13 Threaded Inserts on 3 1 8 BC 4 Places ANSI Class 150 FF 1 1 2 Sunction Flange 1 2 13 Inset Bolts on 3 7 8 BC 4 Places ANSI Class 1...

Page 4: ...nner Magnet 9 Wear Ring Outer Rear 10 Wear Ring Inner Rear 11 Wear Ring Outer Front 12 Wear Ring Inner Front 13 Thrust Washer Front 14 Bearing Forward 15 Bearing Rear 16 Spacer Bearing 17 Shaft 18 O r...

Page 5: ...Rear SC 1 16 105S001 Spacer Bearing Kynar 1 17 060S003 Shaft SC 1 Ref No Part Number Description Qty Pump Ref No Part Number Description Qty Pump 18 530S003 1 O ring Containment Shell Viton 1 530S003...

Page 6: ...g a pressure gage in the discharge piping 7 Clean piping as necessary to remove dirt grit weld slag etc 8 Provide clearance behind motor to remove motor and outer magnet 24 approximately 2 feet 9 For...

Page 7: ...sassembly Work Safety Magnetic drive pumps contain strong magnets which pose risk to people and property Based on this the following must be observed 1 Individuals with cardiac pacemakers should avoid...

Page 8: ...e 3 8 hex nuts inserted in the bottom rear half of case support 20 4 Remove hex bolts 28 29 and then remove the front half of case support 20 5 Insert two flat screw drivers 180 from each other betwee...

Page 9: ...an be removed with the inner magnet attached 10 Remove inner rear wear ring 10 from impeller 7 Figure 4 Figure 5 Figure 6 6 Remove inner magnet and impeller assembly from pump 7 If the inner magnet 8...

Page 10: ...ol 6 Install stator 19 into containment can 6 with counter clockwise rotation left hand thread 7 Install outer rear wear ring 9 into lock pockets and rotate counter clockwise Heat stake in three place...

Page 11: ...ess ring onto the impeller and rotate clockwise to lock If the fit is not tight heat stake the ring to the impeller in three places Remove any raised plastic from heat staking process 13 Assemble inne...

Page 12: ...16 Figure 17 17 Install assembled inner magnet and impeller assembly onto shaft and lower gently into containment can 21 Carefully install case 1 over shaft carefully and onto containment can Press f...

Page 13: ...all case bolts are tight then fully tighten discharge flange support bolts 35 37 Lubricate O ring 5 inside of the suction flange 4 and install suction flange support 38 Guide assembled pump module ove...

Page 14: ...o rotation and restart pump NPSH problems Inlet pressure too low Verify suction pipe is not too long Insufficient Discharge Insufficient flow Fully open suction valves Clogged strainer Clean strainer...

Page 15: ...aid to Wanner Engineering Inc 1204 Chestnut Avenue Minneapolis Minnesota 55403 This warranty does not cover 1 The electric motors if any which are covered by the separate warranties of the manufacture...

Page 16: ...1 Fax 612 332 6937 SCM 991 2400A WANNER ENGINEERING INC 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www stancorpump com email sales w...

Reviews: