P100 Installation

Location

NOTE: The numbers in parentheses are Reference Numbers 

located in the Parts List exploded views of this manual.
Locate the pump as close to the supply source as possible.
Install it in a lighted clean space where it will be easy to inspect 

and maintain. 

Motor and Controller

The P Series pump shaft can rotate in either direction, therefore 

direction of motor shaft rotation is not critical.

Accessories

Consult installation drawing below for typical precision metering 

fluid system components. Contact Wanner Engineering or the 

distributor in your area for more details.

Important Precautions

Adequate  Fluid  Supply.  To  avoid  cavitation  and 

premature pump failure, be sure that the pump will have 

an adequate fluid supply and that the inlet line will not be 

obstructed.  See Inlet Piping on page 6.
Positive Displacement. This is a positive-displacement 

pump. To avoid severe system damage if the discharge line 

ever becomes blocked, install a relief valve downstream 

from the pump. See Discharge Piping on page 6.
Safety Guards. Follow all codes and regulations regarding 

installation and operation of the pumping system.
Shut-Off Valves. Never install shut-off valves between 

the  pump  and  discharge  pressure  regulator,  or  in  the 

regulator bypass line.
Consult the Factory for the following situations:
•   Extreme  temperature  applications  (above  160°F  or 

below 40°F)

•   Pressure feeding of pumps
•   Viscous or abrasive fluid applications
•   Chemical compatibility problems
•   Hot ambient temperatures (above 110°F)

P100

METERING PUMP

W0323

PULSATION

DAMPENER

(OPTIONAL)

CALIBRATION

CYLINDER

Y-STRAINER

ISOLATING VALVE

BALL VALVE

RELIEF

VALVE

FLANGES & MANIFOLDS

BACK PRESSURE

VALVE

(To process)

PRESSURE

GAUGE

P100

METERING PUMP

Summary of Contents for P100

Page 1: ...ervice P100 991 2400B P100 Metering Pump Metallic Pump shown 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www hydra cell com metering...

Page 2: ...ry for performance characteristics of pumps with PTFE diaphragms Consult factory for performance specifications Gallons Per Hour GPH Maximum Flow at Designated Pressure GPH All Pumps GPH Metallic Pump...

Page 3: ...0 1 50 1 60 1 80 1 100 1 W0036 1 2 NPT or 1 2 BSPT 3 8 NPT or 3 8 BSPT OUT IN 5 75 146 1 7 27 184 7 8 61 218 7 9 03 229 4 0 41 10 4 4X 5 65 143 5 4 50 114 3 0 78 19 8 5 90 149 9 6 50 165 1 NEMA 56C 0...

Page 4: ...t the inlet line will not be obstructed See Inlet Piping on page 6 Positive Displacement This is a positive displacement pump To avoid severe system damage if the discharge line ever becomes blocked i...

Page 5: ...more than one pump from the same inlet line Note System back pressure must exceed the pump inlet pressure by at least 15 psi 1 bar in order to prevent flow thru Discharge Piping Hose and Routing Use t...

Page 6: ...tions are tight The oil reservoir beneath the reservoir diaphragm 71 is completely full NOTE The reservoir is filled and sealed at the factory If you are unsure about the oil level remove the cover 70...

Page 7: ...lastic retainer is used Outlet Valve Insert dampening washer 10 valve seat 9 Tetra seal 7 valve 6 spring 5 and spring retainer 4 Install flat Tetra seal O ring 14 between spring retainer 4 and valve s...

Page 8: ...Watch oil level in reservoir If oil gets too low during priming air will be drawn into piston inside hydraulic end Air will cause pump to have loss in flow and repriming will be necessary Fill oil re...

Page 9: ...P100 991 2400B W0039 R O P100 Fluid End Parts List Bolt Torque Specifications Ref No in lbs N cm 1 90 1 017 20 14 158 22 10 113 23 14 158 W0037 W0040 W0038...

Page 10: ...ST 1 D10 020 1017 Valve Seat inlet Hastelloy C 1 D10 020 3300 Valve Seat inlet ceramic 1 14 D10 092 2110 Tetra Seal inlet Buna 1 D10 092 2111 Tetra Seal inlet Viton 1 D10 092 2112 Tetra Seal inlet neo...

Page 11: ...1033 Pump Housing 1 65 D10 085 2210 Key shaft 1 69 D10 038 2210 Plug drain 1 70 F20 105 1020 Cover Nameplate oil reservoir SST 1 71 F20 091 1010 Diaphragm oil reservoir 1 72 G20 090 2010 Screw cap hex...

Page 12: ...1 112 109 Reducer 60 1 ratio 56C 1 112 110 Reducer 80 1 ratio 56C 1 112 111 Reducer 100 1 ratio 56C 1 101 112 112 Kit Protective Cover 1 102 112 116 Kit Output Flange FD 1 103 108 108 101 100 105 103...

Page 13: ...ief valve or repair clean or replace with new relief valve Delivery Too Low and or Erratic Review all Probable Causes and Solutions in Problem 2 No Delivery above Air leak s in inlet line Locate all l...

Page 14: ...Diaphragm Kit 6 9 5 3 2 1 8 4 Kit Designator Part Number Description Qty K D V D03 018 ___ Diaphragm 1 F20 073 ___ O ring outlet manifold 1 F20 074 ___ O ring inlet manifold 1 D03 035 ___ O ring outle...

Page 15: ...t Avenue Minneapolis Minnesota 55403 This warranty does not cover 1 The electric motors if any which are covered by the separate warranties of the manufacturers of these components 2 Normal wear and o...

Page 16: ...Revised 2 2007 2005 Wanner Engineering Inc Printed in USA 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www hydra cell com metering em...

Reviews: