background image

Discharge Mode

The Analyzer X3 and X6 is capable of a single discharge cycle by selecting Discharge Mode.
In the normal discharge mode a constant pre-stored load current (C/5) is applied to the battery until 1volt
per cell has been reached. The result of the measurement is displayed as a percent of capacity. The
capacity of a battery is defined as the amount of current over time. So the discharge result shown by the
Analyzer X3 and the X6 is also given in mAh, the amount of current discharged over time.
The rate at which the battery is discharge is called the (C) rate. 1C is the discharge current amount of the
battery divided by battery capacity. For example: the capacity of a battery is 1200mAh and the discharge
current is 1200 mA, 1C. If the discharge current is reduced to 120 mA, then the C rate is 0.1C.

Use the following procedure to select the

Discharge mode:

ACTION

Display After “Turn On”

After the battery is placed
in the adapter

NO ACTION

NO ACTION

NO ACTION

NO ACTION

NO ACTION

FOR RESULTS

PUSH FUNCTION BUTTON
until battery
specs appear
in the display

PUSH

PUSH

PUSH

CYCLE/AUTO/CONDITION

<FUNCTION> FOR NEXT

DIS-CHRG BATTERY

DIS-CHRG BATTERY

DIS-CHRG

READY

DIS-CHRG BATTERY

CAP= 91% 1501MAH

<FUNCTION> FOR NEXT

HAS BEEN SELECTED

EMPTY

TO PROCEED PRESS

<FUNCTION>

LION 1650 MAH 7.4V

<FUNCTION> FOR NEXT

LION 1650 MAH 7.4V

HAS BEEN SELECTED

QUICK TEST

<FUNCTION> FOR NEXT

13

SELECTING “ DISCHARGE “

RESULTS

To select the Analyzer X3’s and X6’s

follow the directions below:

Charge Mode,

ACTION

Display After “Turn On”

After the battery is placed
in the adapter

NO ACTION

NO ACTION

NO ACTION

NO ACTION

NO ACTION

FOR RESULTS

PUSH FUNCTION BUTTON
until battery
specs appear
in the display

PUSH

PUSH

PUSH

PUSH

CYCLE/AUTO/CONDITION

<FUNCTION> FOR NEXT

DISCHARGE BATTERY

CHARGE BATTERY

CHARGE BATTERY

CHARGING

READY

CHARGE COMPLETED

120 M TOP OFF

<FUNCTION> FOR NEXT

<FUNCTION> FOR NEXT

HAS BEEN SELECTED

EMPTY

TO PROCEED PRESS

<FUNCTION>

LION 1650 MAH 7.4V

<FUNCTION> FOR NEXT

LION 1650 MAH 7.4V

HAS BEEN SELECTED

QUICK TEST

<FUNCTION> FOR NEXT

Charge Mode

The Analyzer X3 and X6 applies two types of charge algorithms for the two types of chemistries.
For Nickel based battery chemistries, a constant current of 1C (changeable with software option) is applied
until the battery voltage peaks and descends negative. A top off current or 0.2C is then applied for 30

minutes to bring the total charge to 100%.

Lithium batteries are charged with a different algorithm. The Analyzer X3 and X6 applies a constant current of
1C until the battery pack voltage equals between 4.1 and 4.2 Volts (the exact voltage depends on the pack
manufacturer’s specification). Upon reaching the predetermined voltage, the voltage is then held constant
allowing the current to decrease to C/11.
The rate at which the battery is charging is called a C rate. The (C) rate is the charging current divided by the

Capacity of the battery . For example: the capacity of a battery is 1200maH and the charge current is

1200 mA, than (C) rate is 1(C). If the charge current is reduced to 120 mA, then the C rate is 0.1C.

14

SELECTING “ CHARGE “

RESULTS

Summary of Contents for X3

Page 1: ...res 4 Specifications 5 Part Overview 6 Understanding the X3 s adapters Cup 7 Getting started 8 Quick Test Analysis 9 Cycle Mode 10 Auto Mode 11 Condition Mode 12 Discharge Mode 13 Learn Mode 16 Safety...

Page 2: ...rges Nickel Cadmium and Nickel Metal Hydride batteries Analyzes and charge lithium Ion and lithium polymer batteries Features a single button capable of multifunction and an easy to read display for a...

Page 3: ...rrent with negative delta V Detection 20x2 2 Backlit LCD Quick Connect Adapter Cups for ease of changing Adapters No tools required Five Memory locations each can be programmed for Li ion NiCD or NiMH...

Page 4: ...e and discharge rate for 4 battery types There is a fifth data position in the cup reserved for user defined information during the Learn Mode See for more information Learn Mode 1 Place a battery int...

Page 5: ...EED PRESS FUNCTION LION 1650 MAH 7 4V FUNCTION FOR NEXT LION 1650 MAH 7 4V HAS BEEN SELECTED HAS BEEN SELECTED QUICK TEST QUICK TEST TEST FUNCTION FOR NEXT ACTION DISPLAY QUICK TEST ANALYSIS 9 Cycle M...

Page 6: ...NCTION FOR NEXT Auto Mode 11 SELECTING AUTO RESULTS SELECTING CONDITION AND RESULTS Condition Mode The CONDITION CYCLE serves basically two needs of Nickel based batteries one is to reform the Cells o...

Page 7: ...ollow the directions below Charge Mode ACTION Display After Turn On After the battery is placed in the adapter NO ACTION NO ACTION NO ACTION NO ACTION NO ACTION FOR RESULTS PUSH FUNCTION BUTTON until...

Page 8: ...modified in the field however by utilizing the function one can learn a non OEM battery It is very important that the battery you are using the LEARN MODE function for must be at least 95 of the state...

Page 9: ...ifferent parameters for the same battery just repeat the Learn mod process again UNKNOWN BATTERY learn mode UNKNOWN GOOD One must observe the proper polarity when connecting the battery to the Univers...

Reviews: