![W&T rule.box 53920 Operating Instructions Manual Download Page 23](http://html1.mh-extra.com/html/wandt/rule-box-53920/rule-box-53920_operating-instructions-manual_3077273023.webp)
23
6. Maintenance
⛳
Open housing
❗
Note: Risk of property damage due to electrostatic discharge
Electrostatic discharges can destroy components on the board. Therefore, if you do
not have ESD equipment, touch the metal surround on the network interface before
opening the housing to establish equipotential bonding.
Some maintenance work requires access to the circuit board. For this purpose,
you can open the housing.
1.
Remove the power supply and network cable.
2.
Dismantle the rule.box from the top-hat rail.
3.
Touch the metal surround of a network socket to perform equipotential bon-
ding.
4.
Gently press the narrow sides of the rule.box housing together so that the
plastic lugs on the long sides of the bezel detach from the body of the
housing.
5.
Pull off the front bezel.
You can now pull the board out of your guide to perform maintenance.
⛳
Restore factory settings on the hardware side
With the help of a jumper inside the device, the rule.box can be reset to the fac-
tory settings.
1.
Open the housing of the rule.box according to the preceding instructions.
2.
Pull the board out of the guide.
3.
In the middle of the board you will find two jumpers, each of which is
connected to only one contact pin.
4.
Close the contact jumper of the jumper pointing to the rear side of the de-
vice.
5.
Supply the board with voltage.
6.
The recovery process is indicated by the following blink code: Short on, long
off.
7.
After successful execution, the flashing pattern is inverted: Long on, short
off.
8.
Disconnect the board from the power supply.
9.
Set the jumper back to the uncontacted initial position.
10.
Close the housing.