background image

Form-Nr. 50669 AEN 

Rev. 004 / 24.10.2018

Subject to alterations

Manufacturer

W&H

 Dentalwerk Bürmoos GmbH

Ignaz-Glaser-Straße 53, 5111 Bürmoos, 

Austria

t

 +43 6274 6236-0, 

f

 +43 6274 6236-55

[email protected] 

wh.com

Summary of Contents for 10217302

Page 1: ...Contra angle handpieces Endea Endo Cursor EB 62 Endea EB 75 EB 79 Contra angle handpieces Endo NiTi WD 73 M WD 74 M Instructions for Use...

Page 2: ...ackaging 5 1 Introduction 6 2 Safety notes 9 3 Product description 11 Endea Endo Cursor 11 Endea NiTi Endea 12 4 Operation 13 Assembly Removal 13 Changing the root canal instrument 15 Test run 16 5 Hy...

Page 3: ...nual cleaning 23 Automated cleaning and disinfection 24 Drying 25 Inspection Maintenance and Testing 26 Packaging 29 Sterilization 30 Storage 32 6 Servicing 33 7 W H Accessories and spare parts 34 8 T...

Page 4: ...in the Instructions for use WARNING risk of injury ATTENTION to prevent damage occurring General explanations without risk to persons or objects Do not dispose of with domestic waste Symbols 4...

Page 5: ...mponent Recognition Mark indicates compliance with Canadian and U S requirements Serial number Date of manufacture XXXX Thermo washer disinfectable Sterilizable up to the stated temperature Caution Ac...

Page 6: ...tients Prior to initial use please read the Instructions for use These explain how to use your medical device and guarantee a smooth and efficient operation Observe the safety notes Intended use Denta...

Page 7: ...the manufacturer The manufacturer can only accept responsibility for the safety reliability and performance of the medical device when it is used in compliance with the following directions The medic...

Page 8: ...in compliance with these Instructions for use The medical device should be prepared for use and maintained by staff who have been trained in procedures for infection control personal safety and patie...

Page 9: ...k the medical device for damage and loose parts each time before using e g push button Do not operate the medical device if it is damaged Only attach the medical device onto the motor when the motor i...

Page 10: ...rior to initial use The medical device is sealed in PE film and not sterilized when delivered The PE film and the packaging are non sterilizable Clean disinfect and lubricate the medical device Steril...

Page 11: ...3 Product description Endea Endo Cursor Endea Endo Cursor Push button w grip profile e sheath 11...

Page 12: ...Endea NiTi Endea push button w grip profile e sheath 3 Product description Endea NiTi Endea 12...

Page 13: ...not assemble remove the medical device during operation Fit the contra angle handpiece onto the motor until it snaps into place wCheck the secure hold on the motor e Remove the the medical device by p...

Page 14: ...e root canal instrument when the medical device is stationary Never touch the rotary instrument while it is still rotating Do not activate the push button of the medical device during operation This l...

Page 15: ...limit stop a and turn until it engages b Endea Endo Cursor Insert the root canal hand instrument Push the press button c firmly at the same time insert the root canal hand instrument until limit stop...

Page 16: ...e at eye level Insert the root canal instrument Start the medical device In the event of operating malfunctions e g vibrations unusual noise overheating stop the medical device immediately and contact...

Page 17: ...national laws directives standards and guidelines for cleaning disinfection and sterilization Wear protective clothing safety glasses face mask and gloves Use only oil free filtered compressed air wi...

Page 18: ...specified by the manufacturer of the disinfectant Use disinfectants which have been tested and found effective by the Verbund f r Angewandte Hygiene e V VAH Association for Applied Hygiene the sterre...

Page 19: ...ainly determined by mechanical stress during use and chemical influences due to processing Send worn or damaged medical devices and or medical devices with material changes to an authorized W H servic...

Page 20: ...on the internal parts Operate the medical device for at least 10 seconds at idle speed Ensure that all outlets are rinsed out Wipe the entire surface of the instrument with disinfectant Remove the ro...

Page 21: ...evice in liquid disinfectant or in an ultrasonic bath Clean the medical device under running tap water 35 C 95 F Rinse and brush off all internal and external surfaces Move moving parts back and forth...

Page 22: ...Hygiene and maintenance Automated cleaning and lubrication W H recommends automated cleaning and lubrication with W H Assistina 3x3 Follow the instructions in the Assistina Instructions for use 22...

Page 23: ...ecommends wiping down with disinfectant Evidence of the medical device s basic suitability for effective manual disinfection was provided by an independent test laboratory using the mikrozid AF wipes...

Page 24: ...rs of washer disinfectors cleaning agents and or disinfectants Evidence of the medical device s basic suitability for effective automated disinfection was provided by an independent test laboratory us...

Page 25: ...Hygiene and maintenance Drying Ensure that the medical device is completely dry internally and externally after cleaning and disinfection Remove any liquid residues using compressed air 25...

Page 26: ...ection Check the medical device after cleaning and disinfection for damage visible residual soiling and surface changes Reprocess any medical devices that are still soiled Sterilize the reassembled me...

Page 27: ...sential after every internal cleaning Before each sterilization or After 30 minutes of use or at least once daily Chucking system once a week With W H Service Oil F1 MD 400 Follow the instructions on...

Page 28: ...Testing after lubrication Direct the medical device downwards Operate the medical device so that excess oil can escape Excess oil may result in the medical device overheating 28...

Page 29: ...ollowing requirements The sterilization package must meet the applicable standards in respect of quality and use and must be suitable for the sterilization method The sterilization package must be lar...

Page 30: ...mmends sterilization according to EN 13060 EN 285 oder ANSI AAMI ST79 Read the notes follow the instructions and heed the warnings provided by the manufacturers of steam sterilizers The program select...

Page 31: ...suitability for effective sterilization was provided by an independent test laboratory using the LISA 517 B17L steam sterilizer Firma W H Sterilization S r l Brusaporto BG and the CertoClav MultiCont...

Page 32: ...Hygiene and maintenance Storage Store sterile goods dust free and dry The shelf life of the sterile goods depends on the storage conditions and type of packaging 32...

Page 33: ...perating malfunctions immediately contact an authorized W H service partner Repairs and maintenance work must only be undertaken by an authorized W H service partner Ensure that the medical device has...

Page 34: ...and spare parts or accessories approved by W H Suppliers W H partners 000301xx W H Assistina 301 plus 19922000 W H Assistina 3x2 MB 200 19923000 W H Assistina 3x3 MB 300 30310000 W H Assistina TWIN MB...

Page 35: ...Root canal hand instruments 3 6 4 min chuck length mm until limit stop max motorspeed rpm 6 000 In choosing the correct operating conditions the user must ensure that there is no risk to the user the...

Page 36: ...h mm einrastend max motor speed for NiTi files from 300 350 rpm produces an application speed of rpm 25 000 357 40 000 312 max motor speed for NiTi files from 600 rpm produces an application speed of...

Page 37: ...tionspeedof rpm 5 000 312 600 300 max motor speed for NiTi files from 600 rpm produces an application speed of rpm 10 000 625 1 200 600 max motorspeedforNiTifilesfrom1 200 2 500rpm producesanapplicati...

Page 38: ...um 50 C 122 F Temperature of the working part rotary instrument maximum 41 C 105 8 F Ambient conditions Temperature during storage and transport 40 C to 70 C 40 F to 158 F Humidity during storage and...

Page 39: ...9 Disposal Ensure that the parts are not contaminated on disposal Instrument disposal Follow your local and national laws directives standards and guidelines for disposal Medical device Packaging 39...

Page 40: ...or material or manufacturing defects within a warranty period of 24 months from the date of purchase We accept no responsibility for damage caused by incorrect handling or by repairs carried out by th...

Page 41: ...Inc 6490 Hawthorne Drive Windsor Ontario N8T 1J9 Canada t 1 800 2656277 1 519 9446739 f 1 519 9746121 E Mail service ca wh com W H Impex Inc 33091 W Jefferson Ave Brownstown MI 48173 USA t 1 800 265 6...

Page 42: ...Form Nr 50669 AEN Rev 004 24 10 2018 Subject to alterations Manufacturer W H Dentalwerk B rmoos GmbH Ignaz Glaser Stra e 53 5111 B rmoos Austria t 43 6274 6236 0 f 43 6274 6236 55 office wh com wh com...