30
5.2 Technical Data
Product Identification Number:
• 0359CO1364 for Danta,
• 0359CP1411 for Koto
5.2.1 Danta 500
Gas type
G20
G20/G25
G25/G25.3
G20/G25
G30/G31
G31
I2H, I2E
I2E+
I2L/I2EK
I2ELL
I3B/P
(30/50)
I3+
I3P
(37/50)
I3P (30)
Supply pressure
mbar
20
20/25
25
20
30/50
28-30/37
37/50
30
Nominal heat input gross (Hs)
kW
7,5
7,5
7,5
7,5
7,1
7,1
7,1
6,0
Nominal heat input nett (Hi)
kW
6,8
6,8
6,8
6,8
6,6
6,6
6,6
5,5
Consumption
m
3
/hr
0,711
0,711/
0,828
0,828
0,828
0,204
0,204
0,261
0,221
Burner pressure (hot)
mbar
11,9
11,9/
18,75
18,75
18,75
28,3
28,3
36,0
29,1
Injector marking
280 (x2)
120 front, 100 rear
Pilot
440-1350-xx (31.2 inj)
440-1350-xx (27.1 inj)
Efficiency class
2
Nox class
5
Type
C11/C31
5.2.2 Danta 800
Gas type
G20
G20/G25
G25/G25.3
G20/G25
G30/G31
G31
I2H, I2E
I2E+
I2L/I2EK
I2ELL
I3B/P
(30/50)
I3+
I3P
(37/50)
I3P (30)
Supply pressure
mbar
20
20/25
25
20
30/50
28-30/37
37/50
30
Nominal heat input gross (Hs)
kW
10,0
10,0
10,0
10,0
8,4
8,4
8,4
7,2
Nominal heat input nett (Hi)
kW
9,0
9,0
9,0
9,0
7,8
7,8
7,8
6,6
Consumption
m
3
/hr
0,937
0,937/
1,09
1,09
1,09
0,234
0,234
0,304
0,261
Burner pressure (hot)
mbar
14,8
14,8/
20,5
20,5
17,0
27,9
27,9
36,0
28,9
Injector marking
380 (x2)
400 (x2)
120 (x2)
Pilot
440-1350-xx (31.2 inj)
440-1350-xx (27.1 inj)
Efficiency class
2
Nox class
5
Type
C11/C31