29
Device control with the automatic control
RH8F Automatic
The primary regulator knob on ash door, to be set in accordance with Table 1
Pic. A (Min.)
Pic. B
Pic. C (Max.)
Between 0 and up to the mark infinitely adjustable control knob to the desired
performance.
Cooking:
The device meets the test of cooking stove EN 12815.
The primary air control should be set according to Table 1
for cooking "cooking" and with the maximum specified
below. Amounts of fuel to operate. The pot must be set to
the predetermined location of the hot plate (Fig.). Avoid
overcooking and fat splashes.
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with pre-
ventive chemicals, furthermore paper and cardboard. For kindling please use wood
scrapings or grill starter but never use liquid auxiliaries!
The first kindling
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
Warning! Upon the first kindling, smoke and unpleasant smell may be gener-
ated. Always ensure the proper ventilation of the room (by opening windows
and doors), and heat the fireplace at maximum rated heating performance. If
with the first heating the maximum temperature is not reached, the above-
mentioned effects may as well arise later on.
•
Before installation pull out the delivery securer off the refractory brick
through the furnace chamber.
Open the door by raising the handle (Picture 11). If the equipment is hot, you can
use insulated gloves. Adjust the primary air regulator (Picture 10), secondary air
regulator and the fuel switch according to the Table 1. Put coal lighter or wood wool
onto the fire grate, followed by wood chips. First insert small pieces of wood, and
then larger ones, light them (Picture 12) and close all the doors again. When the
wood burns quickly, and leaves sufficient glowing embers, put additional fuel on the
fire. Thereafter, adjust the air regulators and the fuel switch according to the Table
1 („Adjustment of the burning air”). The first kindling should be performed “finely”
Summary of Contents for Kamino Trendy RH6F
Page 13: ...13...
Page 16: ...16 Bild 1 RH6F 6kW Bild 2 RH8F 8kW Bild 3 RH8F Automatic 8kW RH6F 6kW RH8F 8kW RH8F Automatic...
Page 17: ...17 Bild 9 Bild 10 Bild 11...
Page 19: ...19...
Page 20: ...20...
Page 21: ...21...
Page 22: ...22...
Page 23: ...23...
Page 24: ...24...
Page 39: ...39 pic 9 pic 10 pic 11...
Page 55: ...55 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14...
Page 74: ...74 Fig 1 RH6F 6KW Fig 2 RH8F 8KW Fig 3 RH8F Automatic NS RH6F 6kW RH8F 8kW RH8F Automatic NS...
Page 75: ...75 Fig 12 Fig 13 Fig 14 Fig 9 Fig 10 Fig 11...