36
3.5
Trouble shooting
Your range is constructed to the latest technical standards.
Nevertheless faults may occur. The reason can be the chimney, the fuel or the emission
pipe system. A short period with a smell and smoke when first starting is quite normal.
Make sure the room is properly ventilated.
Fault
Check/Remedy
The range smokes when
being fired up
in summer
in winter
Open the ash door for a short time (high outdoor
temperature can cause poor draught).
Warm up the chimney with wood wool (either in the
chimney or in the range).
Open the ash door for a short time.
Do not use any damp or smoke intensive fuel.
Fill the fire chamber slowly and a little at a time.
When the range was last cleaned?
Range does not burn properly
Is the chimney draught too weak?
Is the flue connection not sealed properly?
Are all cleaning doors on the range and chimney properly
closed?
Is a fresh air supply ensured from adjoining rooms? (doors
and windows should not be absolutely tight)
Is the chimney overloaded or not sealed properly?
Too low a temperature when
cooking and roasting
Open the ash door for a short time.
Too high a temperature when
cooking and roasting
Add less fuel.
Grate jams when riddling
Have the cinders been removed?
Is there a nail or something jammed in the grate?
Condensation in the range
Is the fuel too damp?
Action in case of chimney fire!
If a chimney is not cleaned often enough, or if the wrong type of fuel is used (e.g. damp
wood) or the air flow is maladjusted the chimney may catch fire. In this case close the air
supply to the fire chamber and call the fire brigade.
Never try to extinguish it yourself using water!
3.6
Spacer connection
If the range is to be incorporated in a fitted kitchen, then the interface between an adjoining
floor cupboard made of wood should be fitted with spacer connections available from the
factory. This thermal spacer has been tested to EN standards together with the range and
complies with the building regulations for fire protection.
The spacer connection is either 55 mm or 110 mm wide and should be mounted on the
range frame as a unit and can be adjusted in height (Fig. 11).
Summary of Contents for K 139F
Page 19: ...19 Bild 6 Bild 7 Bild 8 Bild 9 Bild 10 Bild 11...
Page 37: ...37 3 7 Pictures Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 CLOSE OPEN...
Page 44: ...44 1 2 Structure des appareils K 118 et K 128 K118 K128 K128F...
Page 67: ...67 1 2Struttura dell apparecchio K118 K128 K128F...
Page 90: ...90 1 A t zhely elhelyez se 1 1 A t zhely fel p t se K118 K128 K128 F...
Page 101: ...101 3 6 br k 6 sz bra 7 sz bra 8 sz bra 9 sz bra 10 sz bra 11 sz bra...
Page 106: ...106 ERSATZTEILANSICHT...