37
3. Technical specification
How to connect the Ø 120 mm rear pipe:
1. Remove the top flue pipe stub and the backside cover plate.
2. Mount the rear closing cap of the flue opening tightly on the top.
3. Place the supplied coating plate (see ash-box) on it.
4.Tightly screw the flue pipe stub on the backside.
How to connect the Ø 150 mm rear pipe:
1. Remove the top flue pipe stub and the backside cover plate.
2. Mount the rear closing cap of the flue opening tightly on the top.
3. Place the supplied coating plate (see ash-box) on it.
4. Before doing the backside assembly, fix the adapter on the flue pipe stub with
the screw provided and then firmly tighten the screws on the backside.
Suggestion:
Drive in the retainer screws of the flue pipe on the back up to 3 mm
first and then tighten them firmly (maybe with the adapter fitted) only after putting
on the flue pipe stub.
Type
111 50 / 51 / 53
Nominal performance
5 kW
Heating capacity (m
3
)
-under favorable
-less favorable
-not favorable heating circumstances
according to 18893/TAB2 DIN standard
88
53
34
Flue gas values: fuel:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at nominal performance:
Dust (relating to 13% O
2
)
CO (relating to 13% O
2
)
Efficiency
WOOD / BB7”
5,6 / 5,4 g/s
234 / 320
0
C
12 Pa
< 40 mg/m³
1069 / 825 mg/m
3
82,2 / 79,4 %
Ø 120 mm
The M-Line series can be con-
nected to the chimney in a Ø 120
mm or a Ø 150 mm design. In case
of a Ø 120 mm connection the
connection adapter should be re-
moved from the appliance and it
should be connected without the
adapter.
Summary of Contents for 111 50
Page 10: ...10 Bild 2 Bild 3 Bild 4 Bild 5 Bild 6 Bild 7 ZU OFFEN ...
Page 21: ...21 ...
Page 22: ...22 ...
Page 31: ...31 pic 2 pic 3 pic 4 pic 5 pic 6 pic 7 D open closed ...
Page 38: ...38 3 1 Dimensional drawings 111 50 BOSTON ...
Page 39: ...39 111 51 CHICAGO ...
Page 51: ...51 fig 2 fig 3 fig 4 fig 5 fig 6 fig 7 fermé ouvert ...
Page 72: ...72 fig 2 fig 3 fig 4 fig 5 fig 6 fig 7 Aperto Chiuso ...
Page 89: ...89 1 Használat 1 1 A kandalló felépítése ...
Page 94: ...94 2 kép 3 kép 4 kép 5 kép 6 kép 7 kép BE KI ...
Page 100: ...100 3 Müszaki adatok 3 1 Méretrajzok 111 50 BOSTON ...
Page 101: ...101 111 51 CHICAGO ...
Page 102: ...102 111 53 MANHATTAN ...