![WAMGROUP SEPCOM Vertical Assembly And Main Instructions For Use And Maintenance Download Page 32](http://html1.mh-extra.com/html/wamgroup/sepcom-vertical/sepcom-vertical_assembly-and-main-instructions-for-use-and-maintenance_3317097032.webp)
5.0 INSTALLATION AND FIXING
2
SEP.SEPCOM_Vertical.--.M.A4.0722.EN Issue: A4
07.22
28
SEPCOM
®
Vertical
5.5 Electrical connections and motor wiring diagram
The access to the junction box has to be permitted to specialized personnel only.
Before carrying out the connections make sure the voltage matches the values given on the rating plate.
Make sure the safety standards are followed.
Electric motors features
The connections needs to be made on the junction box of the motor Pos. L.
L
•
During the first start-up phases of the separator make sure the direction of rotation is correct.
Important
Disconnect the power supply before carrying out maintenance operations on the equipment!
Motor terminal diagram
Model
Motor
Power
[kW]
Voltage and
Frequency
Absorption
[A]
Protection
degree
V2-150-3
4
poles
4
220-240V 50Hz
380-420V 50Hz
440-480V 60Hz
8 - 14
IP55
V2-200-3
4
poles
5.5
11 - 19
W2
U2
V2
W2
U2
V2
U1
V1
W1
U1
V1
W1
Higher voltage