4.2 Technical Data
General Data
Size with flat-jet air cap [mm]
130 x 80 x 22
Size with round-jet air cap [mm]
127 x 80 x 22
Weight [g]
ca. 525
Air consumption [l/min]
ca. 150 (at 3 bar; nozzle-
1.0 mm and flat-jet)
Switching time [ms]
ca. 100 (for color marking systems ca. 200)
Energy Supply
Control air pressure [bar]
4.5-6
Atomizer air pressure [bar]
0.5
– 5 (at least 0.5 bar lower than control pressure)
Material pressure [bar]
max. 35
Voltage [VDC]
24
Power consumption [W]
1,8
4.3 Type Label
The type label was etched into the casing. The serial number is
hammered into this label.
5 Installation and Start-up
The valves can be installed in any position. The distance to the application area depends on the desired
application width. An intermitting operation of the device will cause natural oscillations; therefore a solid
installation is most important. Try to avoid excessive natural oscillations (transmission from device to valve).
5.1 Hose Mounting
There are three functional hoses which will be con-
nected as follows:
1 Material to G 1/8-connection (matching screw
connections can be ordered as accessories!)
2 Control air SL to screw connection for 6mm-
hose (21.0.0)
3 Atomizer air ZL to screw connection for 6mm-
hose (21.1.0)