Introduction  

1.1  Target Group of this Manual  

  Operating Personnel  

  Maintenance Personnel 

 

1.2  List of Signs and Symbols 

This  operating  manual  warns  users  of  operations  which  may  put  their  health  at  risk.  The  warnings  are 
indicated by combinations of text and symbols as follows: 

 

 

WARNING 

Signals a possible dangerous situation. 

Death or severe injuries

 

can

 follow, if you do not avoid this situation.

 

 

 

CAUTION 

Signals a possible dangerous situation.  
Slight  or  minor  injuries 

can

  follow,  if  you  do  not  avoid  this  situation.  This  sign  is  also 

used where damage to property is possible.

 

 

 

IMPORTANT 

Indicates tips for usage and other particularly useful information. 

No

 dangerous situation.

 

2  Safety  

2.1  General Information  

The construction of this device is according to the latest technology and is absolutely reliable. The individual 
components as well as the complete device are continuously checked by our quality management. 

2.2  Dangers from Residual Energy  

Please  instruct  the  operating  personnel  on  the  respective  measures  to  be  taken  against  the  occurrence  of 
mechanical, hydraulic, pneumatic and electric / electronic residual energies. 

2.3  Safety Advice  

 

OBSERVE 

Please observe the following safety advice in order to avoid dangerous situations!

 

 

  Assemble  the  controller  in  a  certified  device  before  connecting  it!  Depending  on  the  individual 

assembly situation, an additional touch guard for the terminal contacts may be required according to 
rules and regulations.  

 

  Establish an individual hazard analysis for the integration of the controller into existing processes. If 

necessary, install respective safety equipment in a workmanlike manner.  

Summary of Contents for 979429.02

Page 1: ...troller 230 V AC Article Number 979429 02 NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions This device may only be worked with and...

Page 2: ...5 3 Description of Function 6 3 1 Purpose of the Device 6 3 2 Technical Data 6 4 Initial Start Up 7 4 1 Mounting and Installation 7 4 2 Operating and Display Elements 7 4 3 Interfaces 8 4 4 Wiring Dia...

Page 3: ...declaration loses its validity Manufacturer Walther Systemtechnik GmbH Hockenheimer Stra e 3 D 76726 Germersheim Description Universal Temperature Controller Article Number 979429 02 We declare that t...

Page 4: ...er particularly useful information No dangerous situation 2 Safety 2 1 General Information The construction of this device is according to the latest technology and is absolutely reliable The individu...

Page 5: ...e of the content of this operating manual the user follows the instructions and notes contained in this operating manual the user does not rebuild or make changes on parts of the device without prior...

Page 6: ...ined by the employed sensor type Simple operation and parameterization as well as useful additional functions such as recognition of sensor damage with automatic power cut off alarm output 3 completel...

Page 7: ...nect the consumers relays to the described clamps see p 9 5 3 Connect the control voltage as described check voltage beforehand see p 9 5 3 Parameterize the control unit according to your requirements...

Page 8: ...resistance Cable lengths of up to 50 meters measuring lead can be realized without intermediate transmitter min 3x0 22mm Inlets Control Voltage The supply voltage for the controller is 230V AC 50Hz s...

Page 9: ...easuring range Turn off value Temperature Relays J2 90 0 After selecting confirm your menu settings by pushing SET You will then automatically return to the menu selection or to the control mode Note...

Page 10: ...e active display flashes confirm with SET The display will now switch into the setting mode of the selected menu in this case the setting of the sensor types to be connected The upper display PV will...

Page 11: ...P I D outlet without voltage pulse function only on off cycled 2 Outlet relay programmable as in Mode 0 additionally activated SSR P I D outlet at clamps 6 and 7 voltage impulse outlet approx 10V 3 S...

Page 12: ...I D settings of the connected load For this purpose it is necessary that the control unit is ready to operate the load is clamped on and an uncritical set value for temperature is already set CAUTION...

Page 13: ...1 General Information NOTE First check all supply lines for connectivity and serviceability In case of serious problems that cannot be resolved please contact the Walther Systemtechnik GmbH customer s...

Reviews: