![Walther Systemtechnik SMS-05 Assembly Instructions Manual Download Page 18](http://html1.mh-extra.com/html/walther-systemtechnik/sms-05/sms-05_assembly-instructions-manual_3294926018.webp)
Rev. 1.3
Assembly Instructions
– Spray Valve SMS-05
Page 18 of 31
Walther Systemtechnik GmbH
– D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de
9 Taking out of Service
9.1 Short Interruption
A short interruption (15 min or more) has to be followed by a clean spraying.
IMPORTANT
Please follow the operating instructions!
9.2 Long-term Interruption
The following has to be observed for a long-term interruption of the device/machine:
Depressurize material supply lines
Take off air cap (2.0) and clean nozzle (3.0) with a special thinner and a soft cloth. Make sure that no
cloth fibers are left on the nozzle tip.
IMPORTANT
Please follow the maintenance instructions!
9.3 Shutdown of Device
The following is important for a shutdown of the machine / device:
Clean the spray valve with a special thinner.
IMPORTANT
Please follow the maintenance instructions!