8
5
A) What is included in the box
u
SURFOX machine
u
Hand wand and connecting hose
u
Ground clamp
u
Accessory kit containing:
• 1 90° tungsten tip (already installed on the hand wand)
• 3 high conductivity standard cleaning pads
• 1 PTFE clamping ring
• 1 x 2.5 mm hexagonal key for changing tungsten
cleaning tips
B) Filling the reservoir
Fill the reservoir in the back of the machine with SURFOX
electrolyte solution. The reservoir holds 1.9 L of SURFOX
electrolyte solution.
C) Connecting air supply
Connect the air supply at the back of the machine. Note
that the maximum allowed pressure is 150 PSI max.,
80 PSI min. (1000 KPa). If the air supply is not plugged into
the machine, the machine will still work but there will not be
any fume elimination.
D) Plugging in the power cord
When an extension cord is needed, use wire size 14 (AWG)
for up to 50 feet (15 meters) and size 12 (AWG) for 50 to
100 feet (15 to 30 meters).
E) Plugging in the ground clamp
Plug the ground clamp at the front of the unit. Attach the
clamp to the work piece being cleaned. The cleaning and
passivating process will not work if the part is not properly
grounded.
Start-up procedure
Start-up procedure
Reservoir
Air supply
connector
Ground
clamp