4 Description of Product
Page 12 of 18
Operating Manual Inline Filter WIF-BA-10
EN
Performance Characteristics
•
Available in different mesh widths, depending on the requirement
•
Filter system made of high-quality stainless steel
•
Aggressive media can also be filtered
•
Easy and fast replacement of filter cartridge
•
Reduction of unplanned machine/system standstills due to contaminations in the fluid system
Table 2 gives you an overview of the allowed operating conditions, respectively the limits of use.
Feature
Min
Max
Value
Hydraulic details
Allowed operating pressure
0
-
10
[bar]
Other values
Weight
0,2
[kg]
Dimensions
Ø 20 x 169
[mm]
Material main body
Stainless steel
Table 2 – Operating conditions and limits of use
Installation
IMPORTANT
Make sure that the pipes/lines are suitable for the maximum operating pressure.
Pay attention to the flow direction (Inlet / Outlet).
Only install in line systems
without pressure.
When testing the installation for tightness, do not exceed the maximum allowed
operating pressure of the Inline Filter.
Do not operate the filter if you find damaged components!
When you install an Inline Filter, make sure that the line is not in use and that no pressure is applied.
Now you can properly install the Inline Filter. Pay attention to the flow direction – orientation of arrow.
Figure 3 – Flow direction