background image

 

Replacing TPK Series Mechanical Seal

 

1.

 Removing mech seal.                                                     

WI-D3-S-B019E-1

 

 

Place the pump on work bench with motor down.

 

Mark the number of the intermediate chambers and 
draw a line along with straps.

 

 

Draw the line all the way down to pump casing.

 

Loose the nuts on straps. 
Remove the 2 straps. 

 

Remove the suction intercon-nector.

 

Remove the coupling covers.

 