Injector block and grids:
The injector block and the grids are in contact with high temperatures (up to 1000°C) and
therefore depending on the working hours they will have attrition. To extend the durability
use only allowed fuels. (look chapter permissible fuels)
It is important to build in the injector block in the right direction. The openings have to be
orientated to the doors. (look chapter cleaning of the boiler stove)
Noise:
During the boiler stove is heating up or cooling down, it can get some metal cracking noise
because of the material extensions.
Coating:
Stock the boiler stove only in dry locations and keep it dry until it get installed! The boiler
stove has to be heated up a few times until it`s coating completely cures and protects
the metal parts from corrosion.
Please control the external coating before you install the Walltherm, when you find defect
parts please contact immediately your reseller.
After the installation of the Walltherm
®
we can only resolve the problem with sprays.
To avoid coating problems during the operation please take note of the following tips:
a)
Please clean the external parts only with water and soap, do never use alcohol or
similar aggressive cleaning liquids.
b)
To protect the upper side of the Walltherm
®
please close the exhaust fume flap
when the gas temperature reaches about 300 - 400°C. (look chapter: Using the
boiler stove – Lighting)
Glass (doors):
The glass of the lower door is a wear part, because of the high temperatures of the lower
combustion chamber it can get white and lose the transparency. To have a longer durability
of the glass please put always the protection stone on its position. Look chapter cleaning.
Doors:
Because of high temperatures the stainless steel frame of the doors can change its colour.
The frame can get grinded to recondition the original optic.