WALLTHERM
®
produced and developed by
Walltherm
®
37/64
Thermostat:
For the pump start you can work with a simply thermostat which start´s the pump when
the water inside the heat exchanger raises over 60°C.
Only authorized personal are allowed to do the maintenance for the
fittings (water system) and electric parts.
The pump start can caused by turning the thermostat (0 – 90°C).
The thermostat should be set to (60 – 70 °C), it means by reaching the adjusted water
temperature the pump starts.
A specialized company on electricity needs to connect the thermostat with the heating
pump and through a plug with the electric cable. Please read the exact manual from the
producer of the product.
Example:
Electrical connection of our standard
thermostat with capillary sensor:
Inside the thermostat there are 4 connections. You need to
connect the junctions C and 2 as well as the ground! The
connector 1 remains unused! (obtains only for the Wallnöfer
product.) Wallnöfer does not make any representations
regarding the validity and eventually changes of the product
(see manual thermostat)
Grounding!
Danger: The system must be grounded and fitted with a circuit breaker as provided
for by current laws (fig. circuit diagram).
4.g Information for immuring the insert Walltherm
®
Vajolet Basic
Requirement:
1) Important: the Walltherm
®
should be connected to the chimney and to the water
circuit before housing. The client should use the boiler stove a few time before immuring
it.
2) the chimney sweeper needs to approve the installation.
3) the initial startup must be done by specialists and the installation protocol needs to be
filled out and send to the producer.
4) the client should be able to use the Walltherm
®
and should make a positive result of a
right combustion.
Advices for the housing:
The material for the housing must be heat resisting and fireproof.
(Control the fire protection class, maybe ask the chimney sweeper).
Load capacity: make sure that the floor can resist the weight of the boiler stove
(around 380 kg with water content) and add the weight of the immuring material.